Fig. 1 Greensource with HWDU-151 – function description
1Internal unit
2Underfloor heating system
3Radiators
4Heating circuit pump
5Heat transfer medium pump
6Heat pump
7Expansion valve
8Evaporator
9Compressor
10 Condenser
The fan blows air through the evaporator.
The air meets the refrigerant in the evaporator. At this
point, the refrigerant is in liquid form. The refrigerant
begins to boil as soon as it meets the warmer air. The
resulting vapour is routed into the compressor.
The pressure of the refrigerant increases in the
compressor and the temperature of the gas rises to
approx. +100 °C. The warm gas is then forced into the
condenser.
Energy in the condenser is transferred to the heat
transfer fluid circuit. The gas is cooled down and
becomes fluid. The pressure in the refrigerant is still
high when it is routed to the expansion valve.
Inside the heat pump, the energy is routed to the
heating system (underfloor heating system and/or
radiators) and via the DHW cylinder into the DHW
system of the building.
The refrigerant pressure is reduced by the expansion
valve, from where the refrigerant is routed to the
evaporator. The refrigerant changes back into its
gaseous form whilst it runs through the evaporator.
1
2
3
4
5
6
7
8910
6 720 615 974-60.1I
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Worcester Greensource at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Worcester Greensource in the language / languages: English as an attachment in your email.

The manual is 2.1 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info