809316
6
Zoom out
Zoom in
Previous page
1/16
Next page
6
ROOM THERMOSTAT
A room thermostat may be fitted for control of the central heating
temperature. It will be located in one room of the home. The method
of setting a room thermostat varies with the type and manufacture.
Refer to the instructions supplied with the room thermostat.
THERMOSTATIC RADIATOR VALVES
If thermostatic radiator valves are to be fitted to the system then
they must conform to the requirements of BS2767:1972. It is advisable
to leave one valve permanently set at maximum to prevent the boiler
short cycling.
SHOWERS, BIDETS, TAPS AND MIXING
VALVES
Standard hot and cold taps and mixing valves used with the
appliance must be suitable for operating at mains pressure. The use of
thermostatically controlled or pressure equalising shower valves will
guard against the flow of water at too high a temperature.
Hot and cold mains fed water can be supplied direct to an
overrim flushing bidet subject to local water company requirements.
With all mains fed systems the flow of water from the individual
taps will vary with the number of outlets operated simultaneously
and the cold water mains supply pressure to the property. Flow
balancing using ‘Ball-o-Fix’ type valves is recommended to avoid an
excessive reduction in flow to individual outlets.
For further information contact Worcester Heat Systems Ltd.
HOT AND COLD FLOW
If the flow of water demanded from both hot and cold service
outlets is dependent upon mains supply, it may not be possible in
some installations to operate all outlets simultaneously.
WATER MAINS FAILURE
It is important to note that in the event of a mains water supply
failure, no tap water will be available until the mains supply is
restored. Cistern fed hot water supply will stop once the cistern has
emptied but the appliance can still be used for heating provided that
the system is of the sealed system type. Open vent central heating
systems should be turned off until the supply is restored.
USE IN HARD WATER AREAS
In areas of exceptionally hard water supply it is recommended
that an In-Line scale inhibitor be fitted.
Installation should be strictly in accordance with the
requirements of the local Water Company. An isolating valve to
facilitate servicing should be incorporated.
The water hardness may be determined using the standard test
paper or by reference to the local Water Company.
Further information may be obtained from Worcester Heat
Systems Limited.
AIR SUPPLY FOR OPEN FLUED (O.F.)
APPLIANCES
Your installer will have made arrangements for an adequate
supply of fresh air to the appliance. Fresh air is required for
combustion. Do not block up any air ways which may be let into a wall
or door. Do not hang clothes or other combustible materials over the
appliance or against the flue pipe.
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Worcester-Bosch Highflow 400 Series at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Worcester-Bosch Highflow 400 Series in the language / languages: English as an attachment in your email.

The manual is 1.79 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info