GLOSSARY
6 720 643 356a (2010/10)
12 GLOSSARY
Central heating systems
All radiators must be heated at an even rate. If the top of a radiator is at a lower temperature than the
bottom then it should be vented by releasing air through the venting screw at the top of the radiator.
Ask your installer to show you how this is done.
This boiler is fitted to a sealed system. Should water leaks be found or if excessive venting is required,
then a service engineer must be contacted to inspect the installation and rectify any fault.
Only additives that are compatible with aluminium may be used in the system. Any incompatible
additive used will invalidate the guarantee.
Pluming and Condensate drain
This is a condensing boiler and the flue terminal will, at times give out a plume of water vapour. This
is quite normal.
The boiler produces condensate which is discharged regularly by a syphon within the boiler via a
plastic pipe to a drain. This pipe must not be blocked or altered in any way.
Room thermostat / programmer
A room thermostat / programmer must be fitted to control the central heating. This controls the times
and temperatures of the central heating, preventing the boiler from firing unnecessarily. Refer to the
instructions supplied with the thermostat and programmer for further information.
Thermostatic radiator valves
Thermostatic radiator valves must be fitted in sleeping accommodation. It is recommended that this
type of valve is fitted to all but one of the radiators. The remaining radiator, where the room thermostat
is located, must be uncontrolled and left open.
Pump over run function
After the boiler has finished a demand for central heating or hot water, the pump continues to run for
three minutes to dissipate the heat from within the boiler.
Pump anti-seizure
If there has been no heating demand for 24 hours the boiler will run the system pump for a few seconds
to reduce the possibility of pump seizure during long periods of inactivity.
SEDBUK
Seasonal Efficiency of Domestic Boilers in the UK.
23


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Worcester-Bosch GREENSTAR Si - 2010-2016 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Worcester-Bosch GREENSTAR Si - 2010-2016 in the language / languages: English as an attachment in your email.

The manual is 0.64 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info