Boiler/compartment clearances
Greenstar FS CDi ErP– 6720818078 (2015/12)
4 Boiler/compartment clearances
Your installer will have provided adequate space around the boiler for safety and servicing access.
4.1 Boiler clearances
Clearances
Refer to the figure above and the table below for the minimum
clearances to service the boiler and for an unventilated
compartment.
CAUTION: Restricted space.
The boiler may overheat.
Do not restrict this space with the addition of cupboards, shelves etc. next to the boiler.
item Minimum distance requirements for compartments
1Overall height of compartment
2Overall depth of compartment
3Overall width of compartment
4Height above the boiler to top of compartment
5Depth to front of boiler (or shelf)
6Gap between sides of boiler and compartment
7Gap between shelf and back of compartment
6720818077-08.1Wo
Compartment clearances (mm)
item Servicing Unventilated
1865 900
2 1200 800
3410 600
415 50
5600
1)
1) Can be reduced to 25mm to a removable
surface
200
65 1002)
2) Can be reduced to 50mm on one side but
maintaining the overall 200 minimum
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Worcester-Bosch Greenstar FS CDi Regular at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Worcester-Bosch Greenstar FS CDi Regular in the language / languages: English as an attachment in your email.

The manual is 1 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info