USER INSTRUCTIONS & CUSTOMER CARE GUIDE
INTRODUCTION
8-716-106-255a (03.05)
If a cupboard or compartment which is to be used
for storage or airing is built around the appliance
after installation there must be a non-combustible
partition around the boiler. Further information can
be found in BS 5410 which also describes venting
requirements.
Venting compartments:
Ventilation must be provided for boilers fitted
into compartments as described in BS 5410
A minimum of 2 air vents must be fitted, one at
low level and another at high level onto the same
wall using the same air for circulation.
Free air must not be taken from a room or internal
space containing a bath or shower and must not
communicate with a protected area such as a
hall, stairway, landing, corridor, lobby, shaft etc.
Air vents must allow access for clean free air
and must be sited to comply with the flue terminal
position requirements.
Air ducting runs must not exceed 3m.
Low level air vents must be less than 450mm
from the floor.
A warning label must be added to the vents with
a statement to the effect: ''Do not block this vent.
Do not use for storage'.
Internal* ventilation
High
Level
Low
Level
kW
External** ventilation
High
Level
Low
Level
18/25 220 330 110 220
18/25 220 220 110 110
Internal* ventilation
High
Level
Low
Level
kW
External** ventilation
High
Level
Low
Level
GENERAL INFORMATION
6
GENERAL INFORMATION
*Internal air to and from a space/room inside the building.
**External air to and from directly outside the building.
Conventional flue:
Room Sealed flue:
MINIMUM AIR VENT AREA (cm²) FOR
APPLIANCES INSTALLED IN A COMPARTMENT:
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Worcester-Bosch Greenstar Danesmoor Floorstanding - 2005-2016 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Worcester-Bosch Greenstar Danesmoor Floorstanding - 2005-2016 in the language / languages: English as an attachment in your email.

The manual is 0.45 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info