Installation
Comfort I – 6720810964 (2017/02)
Programmer/boiler connection
The Comfort I RF connects to your boiler’s EMS BUS
connections.
Run a two core cable from the boiler to the Programmer.
Use an electrical cable with a minimum rating of H05VV-F.
For cable runs up to:
100 metres, use 0.50mm2 conductor cross sectional area
300 metres, use 1.5mm2 conductor cross sectional area
Connect the cable to the EMS bus point connections on the
boiler control circuit board, refer to the Installation,
Commissioning and Servicing instruction manual for your
boiler to locate the EMS connections.
Optional wall mounting kit
Using the wall plate as a template, mark the position of the
mounting screws.
The optional wall mounting kit contains:
2 x countersunk screws
2 x plastic wall plugs
Wall plate
•Top retainer
Drill two holes to suit the size and depth of the wall plugs
▶Fit the wall plugs
Feed the two core cable through the back of the wall plate
Fit the wall plate [1], ensuring that it is level and tighten the
screws to secure
Connect the two core cable to the terminal block, one core
to each outer connection, ignore the middle connection
Fig. 3 Suggested Programmer wall plate mounting
Engage the four clips on the back of the Programmer [2]
with the four slots on the wall plate as shown in figure 4
Push the Programmer down into the wall plate to secure
Engage the tabs on the top retainer [3] into the slots on the
wall plate [1] and push down onto the Programmer
Fig. 4 Fitting Timer to wall plate assembly
NOTICE: EMS Connections
The Programmer must NOT be
connected to the boiler’s 230 volt
supply or an external 230 volt supply.
Ensure that the EMS cable is at least
100mm away from any power cables to
eliminate any mains interference
EMS connections are not polarity sensitive
The Comfort I RF connects to your boiler’s EMS
BUS connections only, on an edge connector
identified either with B B or .
6720810964-24.1Wo
6720810964-25.1Wo
1
2
3
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Worcester-Bosch Greenstar Comfort I RF - 2023 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Worcester-Bosch Greenstar Comfort I RF - 2023 in the language / languages: English as an attachment in your email.

The manual is 3.36 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info