OPERATING THE APPLIANCE
GREENSTAR CAMRAY KITCHEN & KITCHEN SYSTEM 12/18 - 18/25 - 25/32
8 716 114 498a (10.07)
11
OPERATING THE APPLIANCE
FAULT CONDITIONS:
The Demand and Lockout lights can indicate some
basic fault conditions:
Normal operation:
a) Demand light:
Light ON - Demand for heat from the
heating/hot water system.
Light OFF - Boiler not firing, no demand
from heating/hot water system.
Demand and Lockout lights:
b) Both lights ON, boiler not firing:
1. Check oil level in the oil storage tank.
2. Press button (B). Boiler should fire.
3. If no response, wait 2 minutes - press
reset button (B) again.
4. If lockout light stays on, do not attempt
further resets. Contact your service
engineer for advice.
c) Both lights OFF, boiler not on, no heating/hot
water:
1. Ensure there is a power supply to the boiler.
2. Check the programmer is set to ON for
heating.
3. Check the setting of the room thermostat,
boiler temperature control/tank thermostat.
4. Press reset buttons (C and D).
5. If the demand light stays off contact your
service engineer for advice.
CAUTION: If the burner will not light repeated
pressing of the lockout reset button can damage
the burner. Always allow 2 minutes between resets.