OPERATING THE APPLIANCE
FAULT CONDITIONS:
The Boiler mode and Lockout lights can indicate
some basic fault conditions.
1 Accessing Controls:
Undo the screws on the bottom of the
front panel using the tool provided. The
panel will drop down and can be removed.
2 Normal operation:
Boiler mode light ON
The appliance is in boiler mode, with a demand
for heat from the controls.
3 Both lights on:
Boiler not firing
Check the level in the oil tank.
Press the Reset button (A). The boiler
should fire.
If there is no response, wait 2 minutes and
press the Reset Button (A) again.
If Lockout light stays on, do not attempt
further resets. Contact your Service
Engineer for advice.
4 Boiler mode light on, lockout light off:
Boiler not on -
No heating/hot water
Press Reset Button (B), press Reset Button
(C) both are below the fascia.
If the boiler remains off, contact your Service
Engineer for advice.
If this fault re-occurs contact your Installer or
Service Engineer.
5 Both lights off:
Boiler not on -
No heating/hot water
Ensure there is power supply to the boiler.
Check the programmer is set to ON and
thermostat is calling for heat.
Ensure that the Service switch is in Boiler
mode.
If there is power supply to the boiler contact
your service engineer for advice.
2 NORMAL OPERATION:
3 BOTH LIGHTS ON:
4 BOILER MODE LIGHT ON LOCKOUT LIGHT OFF:
5 BOTH LIGHTS OFF
1 ACCESSING CONTROLS:
OPERATING THE APPLIANCE
GREENSTAR CAMRAY EXTERNAL 12/18 - 18/25 - 25/32
8 716 112 711b (09.07)
9
USING YOUR
APPLIANCE
A
BC