809320
13
Zoom out
Zoom in
Previous page
1/24
Next page
Clearances and ventilation information
13
Greenstar 2000 – 6 721 839 343 (2023/04)
7 Clearances and ventilation information
7.1 Appliance clearances
Your installer will have provided adequate space around the appliance
for operation, safety and servicing/maintenance access.
The following detail the necessary clearance around the appliance for
service and maintenance.
WARNING
Risk of injury due to damage to the boiler
Heat-producing kitchen appliances must not be operated directly
underneath the boiler.
CAUTION
Risk of damage to appliance or property
The appliance will overheat if the clearance space around the appliance
is restricted by objects.
Do not restrict this space with the addition of cupboards, shelves etc.
next to or around the appliance.
Do not store any combustible materials on or next to the appliance,
such as clothes, towels, paper or plastic bags.
Fig. 10 Appliance minimum clearances
Table 6 Appliance minimum clearances
Reduced front maintenance minimum clearances
The front servicing clearance for this appliance can be reduced to
450mm.
For installations with a front servicing clearance less than 600mm
(minimum of 450mm), the following additional criteria must be
achieved.
The bottom of the appliance case must be between 1000mm and
1500mm from the floor.
There must be at least 450mm clearance in front of the appliance to
floor level. Anything sited below the appliance must not protrude into
this clear space.
There must be at least 200mm clearance to any structure which is
sited below the appliance.
There must be at least 300mm clear space to either the left hand or
right hand side of the appliance. This clear space must be from the
required clear height above the appliance to floor level.
This clearance will not apply if the appliance is sited within
300mm of a door way and the door frame is the only obstruction.
Minimum clearances must be observed to any obstruction/ surface,
(dark shaded areas, figures 11 and 12).
0010012940-001
Minimum clearances
Description Dimensions (mm)
X Appliance width 400
YAppliance height 724 1)
1) Side panel height = 710mm.
Z Appliance depth 300
Maintenance
1Overall clearance height 1094/1134 2)
2) Height for either 60/100 flue or 80/125 flue.
2 Overall clearance depth 900 3)
3) This can be reduced by 150mm (refer to Reduced front maintenance minimum
clearances).
3In front of appliance 600 3)
4 Overall clearance width 410
5Above the appliance 170/210 2)
6Either side of appliance 5
7Below the appliance 200
8Compartment depth 320 4)
4) Clearance to a combustible material.
9Appliance to removable door 20
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Worcester-Bosch Greenstar 2000 - GR2301iW at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Worcester-Bosch Greenstar 2000 - GR2301iW in the language / languages: English as an attachment in your email.

The manual is 3.86 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info