Service and spares
GREENSPRING CWi47 – 6 720 646 322 (2015/04)
Remove the six screws from the back cover of the control
unit (Fig.
68, [2]).
Fig. 68 Location of the fuses inside the control board
After checking the fuses, reinstall all parts in reverse order.
10.3 Condensing heat exchanger unit
Fig. 69 Condensing heat exchanger unit
Condensing heat exchanger unit maintenance;
Shut off power. Disconnect power cord.
Close cold water supply inlet isolation valve and open a hot
water tap to release pressure and drain.
Disconnect the condensate tube (Fig. 70, [1]) and all inlet,
outlet pipes (Fig.
70, [2]) from the condensing heat
exchanger unit.
Remove two hex screws (Fig. 70, [3]) and two Philips
screws (Fig. 70, [4]).
Fig. 70 Removing the condensing heat exchanger
Remove the condensing heat exchanger unit from the
appliance by pulling it towards you.
Flush, clean and inspect condensing heat exchanger. If
deterioration is detected or dirt can not be removed,
dismantle all parts of the heat exchanger for detailed
inspection and cleaning.
Fig. 71 Condensing heat exchanger
The condensing heat exchanger unit must be
checked once a year. Only a qualified
engineer should inspection and maintain the
condensing heat exchanger.
6720801916-04.1V
6720646322-01.1V
4
5
3
3
4
2
1
2
51


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Worcester-Bosch GREENSPRING CWi47 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Worcester-Bosch GREENSPRING CWi47 in the language / languages: English as an attachment in your email.

The manual is 5,96 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info