Installation
6720813171 (2016/05) 27
Fig. 42 Terminal strip connections
[1] Room controller RC and EMS bus (connection colour orange)
[2] Outdoor-temperature sensor (connection colour blue)
[3] Connection terminal for potential free heat demand (connection
colour green)
[4] DHW temperature sensor (connection colour grey)
[5] External switch contact, potential free, e. g. for floor heating
(connection colour red) (thermal protection)
[6] Connection for external three-way valve
[7] External heating pump 230 V (connection colour green) (for use
with non Worcester pump group)
[8] DHW pump 230 V (connection colour grey)
[9] DHW Circulation pump 230 V (connection colour lilac)
[10] Mains connection 230 V AC (connection colour white)
General control connection
The following controls can be connected to the boiler.
Control with contact for potential free heat demand
RC25, RC35 room controller
4121, 4122, 4323 cascade controller
Error reporting module EM10, 0 – 10 V input (can be used to convert
a 0 – 10 V signal to a modulating signal).
Connecting and installing a modulating control (room controller)
Fig. 43 Terminal strip – RC room controller and WA potential-free heat
demand
Installing an RC35 room controller as an outdoor temperature-
dependant control in the boiler
For outdoor temperature-dependant control operation only: it is
possible to install the room controller (e.g. RC35) in the boiler. In this
case, the controller does not have to be connected to the terminal strip
afterwards. If you would like to use this room controller for room
temperature-controlled operation, the room controller must be installed
in a living room.
Push the arrow on the control panel cover to open ( fig. 44).
Fig. 44 Opening the control panel
Remove the cover [1].
Install the RC35 in the slot [2].
Fig. 45 Remove the cover and install the room controller in the boiler
(only for outdoor temperature-dependant operation)
Installing and connecting other controllers outside the boiler
Install the controller as described in the relevant installation
instructions.
Connect a RC25 or RC35 room controller or a 4121, 4122 or 4323
cascade controller to the orange RC terminal using a 2-core cable of
0.75 mm².
Fig. 46 Terminal strip – Room controller RC and EMS bus (connection
colour orange)
It is not possible to connect more than one room
controller ( fig. 43).
PK PS PZ
Mains
230 V
RC WA EV
FA FW DWV
10
6 720 648 726-042.1TD
9876
54321
RC WA
6 720 648 726-043.1TD
If you install the room controller (e.g. RC35) in the
boiler, only outdoor temperature-controlled operation is
possible. See the room controller user manual for further
information.
This connection is reverse-proof. This means that it does
not matter in which order the wires are connected.
6 720 648 726-044.1TD
6 720 648 726-045.1TD
21
RC
6 720 648 726-046.1TD
27


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Worcester-Bosch GB162-80 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Worcester-Bosch GB162-80 in the language / languages: English as an attachment in your email.

The manual is 5,43 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Worcester-Bosch GB162-80

Worcester-Bosch GB162-80 Installation Guide - English - 12 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info