GENERAL
INFORMATION
To ensure you get the very best from your new Worcester
Danesmoor oil boiler, please read these notes and instructions
carefully.
ELECTRICAL CONNECTION
A mains cable should be connected to a double pole isolator
with a contact separation of 3 mm on all poles and supplying the
appliance and controls only.
The mains supply for your Danesmoor boiler is 230/240 volts
AC-50Hz.
Your boiler must be earthed and protected by a 5-amp fuse.
OPEN-FLUED BOILERS
Your installer will create airways (in walls or doors) to ensure
an adequate supply of fresh air to the boiler for combustion. Do
not block these airways, and never hang clothes or other
combustible materials over the boiler or against the flue pipe.
Never place anything on top of the boiler.
ROOM-SEALED BALANCED FLUE
BOILERS
Air for this type of boiler is supplied via the balanced flue
terminal, and no other air supply is required, except for ventilation
if the boiler is installed in a cupboard or compartment.
ROUTINE MAINTENANCE
It is essential that your boiler is installed and serviced by a
competent heating engineer, and Worcester Heat Systems will be
pleased to arrange regular servicing and a comprehensive
maintenance contract.
Alternatively, the Oil Firing Technical Association for the
petroleum industry (OFTEC) will gladly advise you of engineers
trained by and registered with OFTEC.
Servicing should be carried out at least once a year for boilers
which burn 28-second kerosene, and twice a year for boilers which
burn 35-second gas oil.