3061331_201305
Schaltplan MGK-170 - 300
5
4
3
3
2
2
1
1
M2 (Ventilator)
gn/ge
br
br
bl
ws
gn
2
1
1
2
E1 (Zündeinheit)
B3 (Ionisation)
bl
br
gn/ge
sw
Brenner
Netz
Kondensat-
pumpe
Gehäuse
blau
Brücke
Störmeldung
Kondensatpumpe
21
1
2
Y0 (Gaskombiventil)
Y2
Y1
X10
(Schutz-
leiter-
klemme)
3
4
5
2
1
3
2
1
L
N
LN LLNLNLNLN
+- ~ +- +-~~~~~ +
-
++
-
~~~++-
Netz
Ausgang A1
Zubehör
V1
V2
HK-Pumpe
Zündung
Ventilator
Ionisation
eBUS
eBUS
eBUS-Stecker
gn
ge
rt
GND
GND
R680
12V
+
+
-
-
eBus
Eingang E1
Außenfühler
Rücklauffühler
TW-Abgas
TW-Vorlauf
Vorlauffühler
PWM
Drehzahl
GND
3WU-WW
3WU-HZ
Masse
Speicherfühler / Hallsensor
GND
12VDC
B2
(Rücklauf-
fühler)
S2
(TW-Abgas)
S4 (Abgas-
druck-
wächter)
>
X1
X2
X3
X6
X4
X7
X5
X9
(Parameterstecker)
X8
br
gn
grau
schwarz
ws
B 4.1 Speicherfühler
br
ws
gn
br
gn
ws
ge
ws
br
gn
br
gn
ge
ws
ge/gn
sw
bl
br
bl
br
bl
bl
br
sw
br
bl
sw
ws
sw
bn
rs
br
ws
gr
gn
ge
ws
ge
gn
br
A2
A1
br
bl
ws
sw
gn/ge
ge
AF
E1
eBUS
+
-
1
2
a
b
Netz
Z
A1
N
N
N
L1
L1
L1
o ooooo
MT
3,15 A
F1
12 12
12
br
bl
gn/ge
sw
ws
rt
L1
N
gn
ws
gr
rs
br
ge
L1
N
L1
N
L1
N
L1
N
rt
rt
B1
(Vorlauf-
fühler)
S1
(TW-
Vorlauf)
>
ws
ge
gn
br
S3
(Wasser-
druck-
schalter)
P<
P>
2
2
1
1
1
2
3
3
3
S5
(Gasdruckwächter)
P>
1
2
3
Anschlusskasten:
Netz 230VAC 50Hz
Z Heizkreispumpe
A1 kongurierbarer Ausgang
E1 kongurierbarer Eingang
eBus Busanschluss für externes
Regelungszubehör
AF Außenfühler
A1 Regelungsplatine
A2 LED Platine
B1 Vorlauffühler
B2 Rücklauffühler
B3 Ionisationselektrode
B4.1 Speicherfühler
E1 Zündeinheit
F1 Netzsicherung
M2 Ventilator
S1 TW - Vorlauf
S2 TW - Abgas
S3 Wasserdruckschalter
S4 Abgasdruckschalter
S5 Gasdruckwächter
X9 Parameterstecker
X10 Schutzleiterklemme
Y0 Gaskombiventil
5 A
45


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Wolf MGK-250 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Wolf MGK-250 in the language / languages: German as an attachment in your email.

The manual is 1,14 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info