813085
17
Zoom out
Zoom in
Previous page
1/83
Next page
Bedienungsanleitung Steuerung S4_2006_09_25-neu.doc Page 17 / 83
© wodtke GmbH Tübingen. All rights reserved. Subject to change without notice. Month of issue xx/2007 Art. No. 950 281
5.6 Appliance types and programmes
wodtke stoves have different software programmes installed depending on the model. The
programme number appears for a few seconds on the display after switching on the appliance
via the I/O key. The present operating manual only applies with the initially installed software
(you can check this from menu level 1 – see Chapter 0).
P1 (Programme 1): Airplus appliance; thermal output 2 - 6 kW
P2 (Programme 2): Airplus appliance; thermal output 2 - 8 kW
P3 (Programme 3): Waterplus appliance; thermal output 2 - 10 kW
Each programme exists in different versions (updates). The
programme version is indicated by the number in the second line.
5.7 Operating states & functional messages
A distinction must be made between different operating states and functional messages. The
display tells you at any time under which programme your appliance is operating.
Manual operation / Appliance switched off via I/O key: message “stand-by dot “
Automatic operation / Appliance switched off via external controller: (message
HE OFF”)
A
5.7.1 Overview of functional messages (normal operation)
Function Operating state
. “Stand-by dot”, manual operationappliance switched off via I/O key
H E OFF Automatic operation
Appliance switched off via external controller
T W OFF Automatic operation (only with Waterplus appliances) appliance switched off via internal
controller
A -15 Ignition programme countdown in minutes
AI 15 Ignition starta in x minutes (swaps with G off) countdown in minutes
H 4.5 Heating programme
with manual output selection display of thermal output in kW
H M 2.0 Modulation heating programme via external controller (2-stage)
display of thermal output in kW
H.M 2.0 Heating modulated by internal controller (safety function = 1 dot lights up between H and M)
display of thermal output in kW
H E 4.5 Modulation heating programme via external controller (continuous controller)
display of thermal output in kW
R 120 Cleaning programme countdown in seconds
G OFF Fan after-run (15 minutes duration)
5.8 Manual operation / appliance switched off via I/O key
= display shows “stand-by dot” in top right field
= ready to be switched on manually
= not ready for external controller / automatic operation!
= thermal output adjustable, functional values available via “Menu”
After proper installation and connection to the mains the display should show
“G Off” for fan after-run or (if fan after-run has already ended) the “stand-by
dot”. When it appears alone the “stand-by dot” at the top right indicates that
P3
400
Programme
Programme
version
.
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Wodtke Frank waterplus S4 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Wodtke Frank waterplus S4 in the language / languages: German as an attachment in your email.

The manual is 3.18 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Wodtke Frank waterplus S4

Wodtke Frank waterplus S4 User Manual - German - 76 pages

Wodtke Frank waterplus S4 User Manual - French - 80 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info