Bedienungsanleitung Steuerung S4_2006_09_25-neu.doc Page 6 / 83
© wodtke GmbH Tübingen. All rights reserved. Subject to change without notice. Month of issue xx/2007 Art. No. 950 281
As a practical guide value, the largest of our Waterplus appliances (10 kW nominal heating
capacity) is capable of generating a maximum 15,000 kWh per year. This is equivalent to 1500
full load operating hours without interruption at a thermal output of 10 kW. Note that when
delivered by an appliance of our “Topline” series, 40% (= 6,000 kWh) of this thermal output
would go towards heating the room of installation, while with an appliance of our series “Smart”
“PE” or “CW 21” the share of heat delivered to the room of installation would be around 20%,
i.e. 3,000 kWh. This must be taken into account in the planning phase by ensuring that
the room of installation is sufficiently large. The following section contains recommendations
for minimum room sizes and suggestions for alternative solutions for smaller rooms of
installation.
2.2 Minimum room sizes
For all wodtke pellet stoves, the room of installation should at minimum have a floor area of 10
and a room volume of 15 m³. With Waterplus appliances one must also take into account
that the room of installation is additionally heated through heat radiation and convection. The
following guide values apply in this case:
Topline Waterplus appliances (60% of thermal output delivered to water*):
room of installation should account for at least 50% of total heated floor area
Smart / PE / CW 21 Waterplus appliances (80% of thermal output delivered to water*):
room of installation should account for at least 30% of total heated floor area
If the room of installation is too small or the hot water demand to high, the room of installation
will become overheated.
Heating surfaces in the room of installation of a Waterplus appliance: If solar energy
plants or buffer storages are used for auxiliary heating, then the room of installation of the
Waterplus appliance must have additional heating surfaces (radiator, floor heating) so that it can
be heated even when operation of the boiler is not required. This can be the case in
interseasonal periods, for example: In autumn the solar plant delivers sufficient energy to
charge up buffer storage completely. The pellet stove boiler can then remain switched off
because the room of installation can be heated via a radiator using energy from the buffer
storage. This would not be possible without a radiator in the room of installation.
Proposed solution when installing Waterplus appliances in small rooms: If you have opted
for a Waterplus device and the designated room of installation does not meet the above
requirements, you can use a clock or room thermostat that
pellet stove boiler
radiator
heating circuit
chimney
Schematic drawing without buffer storage, control and hydraulic
equipment, installations room etc.
*nominal thermal output rating given in accordance with DIN 18891 (draft to DIN 18894)
room or interconnected rooms
of installation)
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Wodtke Frank waterplus S4 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Wodtke Frank waterplus S4 in the language / languages: German as an attachment in your email.

The manual is 3.18 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Wodtke Frank waterplus S4

Wodtke Frank waterplus S4 User Manual - German - 76 pages

Wodtke Frank waterplus S4 User Manual - French - 80 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info