813149
76
Zoom out
Zoom in
Previous page
1/83
Next page
Bedienungsanleitung Steuerung S4_2006_09_25-neu.doc Page 76 / 83
© wodtke GmbH Tübingen. All rights reserved. Subject to change without notice. Month of issue xx/200x Art. no. 950 281
12 Technical Data
Frank
Airplus PE
04.5 E –
round door
Smart
Airplus PO
04.6 E
Smart
Waterplus
PO 04.6 E
WW
CW 21
Airplus PO
04.7 E
CW 21
Waterplus
PO 04.7 E
WW
PE Airplus
PE 04.6 E
PE
Waterplus
PE 04.6 E
WW
Topline
Airplus PO
04.8 E
Topline
Waterplus
PO 04.8 E
WW
Weight including
panels
c. 108 / 112
kg (steel) c.
116 / 120 kg
(ceramic) c.
139 / 143 kg
(soapstone)
c. 110 kg c. 130 kg c. 121 kg c. 141 kg Body without
panels c.
123 kg
Body without
panels c.
137 kg
c. 108 / 180
kg (steel) c.
116 / 220 kg
(ceramic) c.
139 / 250 kg
(soapstone)
c. 108 / 180
kg (steel) c.
116 / 220
kg
(ceramic) c.
139 / 250
kg
(soapstone)
Dimensions: width x
height x depth
(approx. dim. in mm)
520 x 938 x
535 / 590 520 x 940 x 540 790 x 1000 x 560 660 x 1168 x 565without
telescopic hopper 660 x 1132 x 585
Exhaust pipe
(horizontal, below) Ø 100 mm
Nominal thermal
output(setting
range) 3)
6 kW
(2 – 6 kW) 6 kW
(2 – 6 kW) 10 kW
(2 – 10 kW) 6 kW
(2 – 6 kW) 10 kW
(2 – 10 kW) 6 kW
(2 – 6 kW) 10 kW
(2 – 10 kW) 8 kW
(2 – 8 kW) 10 kW
(2 – 10 kW)
Air/water output
ratio at nominal
output3) 100%: 0% 100%: 0% 20% : 80% 100% : 0% 20% : 80% 100% : 0% 20% : 80% 100% : 0% 40% : 60%
Volume of fuel
hopper2) c. 25 kg c. 25 kg c. 25 kg c. 52 kg c. 52 kg
min. c. 38.5
kg, max. c.
55 kg
telescopic
hopper
min. c. 38.5
kg, max. c.
55 kg
telescopic
hopper
c. 50 kg c. 50 kg
Fuel consumption
(min. / max. thermal
output) 2)
c. 0.5 kg/h /
c. 1.5 kg/h c. 0.5 kg/h /
c. 1.5 kg/h c. 0.5 kg/h / c.
2.5 kg/h c. 0.5 kg/h /
c. 1.5 kg/h c. 0.5 kg/h / c.
2.5 kg/h c. 0.5 kg/h / c.
1.5 kg/h c. 0.5 kg/h / c.
2.5 kg/h c. 0.5 kg/h / c.
2 kg/h c. 0.5 kg/h /
c. 2.5 kg/h
Operating hours
from one filling
(min. / max. thermal
output) 2)
c. 50 h / c.
16 h c. 50 h / c.
16 h c. 50 h / c.
10 h c. 100 h / c.
30 h c. 100 h / c.
20 h
c. 110 h / c.
35 h at max.
telescope
length
c. 110 h / c.
22 h at max.
telescope
length
c. 100 h / c.
25 h c. 100 h / c.
20 h
CO content of flue
gas 3) < 0.01 Vol %
Flue gas mass flow
(min. / max. output)
3)
6.0 g/s / 6.0
g/s 6.0 g/s / 6.0
g/s 6.4 g/s / 9.5
g/s 6.0 g/s / 6.0
g/s 6.4 g/s / 9.5
g/s 6.0 g/s / 6.0
g/s 6.4 g/s / 9.5
g/s 6.4 g/s / 9.5
g/s 6.4 g/s / 9.5
g/s
Flue gas
temperature
(min. / max. output)
3)
157 °C /
229 °C 157 °C /
229 °C 55 °C /
140 °C 157 °C /
229 °C 55 °C /
140 °C 157 °C /
229 °C 55 °C /
140 °C 80 °C /
180 °C 55 °C /
135 °C
Required chimney
draught3) 0 Pa
Design type 1 YES – use of several stoves via one chimney possible
Recommended
chimney diameter 120 mm dia., moisture resistant, with condensate runoff; calculation according to DIN 4705 or EN required
Tests (a selection) DIN 18891; DIN 4702;DIN 4751; EN 303-5; §15a-BVG (Austria)
Approvals CE mark/ VKF/AEAI approval
Approved fuels
Wood pellets with ash content < 0.5%
and tested acc. to DIN-PLUS, DIN 51731 or Austrian standards
calorific value Hu = 4.7-5.2 kWh/kg / diameter < Ø8 mm / bulk density > 650 kg/m³ if possible
Room heating
capacity(min. / max.
output) assuming a
heating demand of
50 W/m2
40 / 120 m² 40 / 120 m² 40 / 200 m² 40 / 120 m² 40 / 200 m²
40 / 120 m²
with ext.
heat
exchanger
(for ex.
ceramic
flueway) 40 /
150 m²
40 / 200 m² 40 / 160 m² 40 / 200 m²
Electric power
consumption < 50 W (ignition briefly c. 250 W)
Supply voltage /
fuse 230 V (50 Hz) / 5 A quick-acting
Volume of water
heat exchanger n.a. n.a. c. 4 litres n.a. c. 4 litres n.a. c. 4 litres n.a. c. 4 litres
Max. operating
pressure/ max.
operating
temperature
- - 3 bar /
100 °C - 3 bar /
100 °C - 3 bar /
100 °C - 3 bar /
100 °C
Temperature
controller
(H.M)temperature
sensor
(TW)temperature
cutoff (STB)
-
-
95 °C
-
-
95 °C
75 °C
85 °C
95 °C
-
-
95 °C
75 °C
85 °C
95 °C
-
-
95 °C
75°C
85 °C
95°C
-
-
95 °C
75 °C
85 °C
95 °C
Heat exchanger
resistance at 600 l/h
flow rate c. 140 mbar c. 140 mbar c. 140 mbar 160 mbar
1)
7.5 kW with ceramic flueway.
2)
depending on pellet geometry and bulk density.
3)
according to DIN tests
76


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Wodtke Frank S4 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Wodtke Frank S4 in the language / languages: German as an attachment in your email.

The manual is 3.18 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Wodtke Frank S4

Wodtke Frank S4 User Manual - German - 76 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info