813077
71
Zoom out
Zoom in
Previous page
1/83
Next page
Bedienungsanleitung Steuerung S4_2006_09_25-neu.doc Page 71 / 83
© wodtke GmbH Tübingen. All rights reserved. Subject to change without notice. Month of issue xx/200x Art. no. 950 281
Disconnect cable of air flow sensor from air flow sensor. Release both screws of the carrier
plate at the suction pipe and carefully remove the air flow sensor together with the carrier
plate by pulling upward, taking care not to damage the tip. Carefully remove any dust or dirt
deposit by blowing or using a paint brush.
Note:
Do not release the small screws that fasten the air flow sensor (circuit board) to the carrier
plate.
Reassembly is done in the reverse order of assembly.
Important notes:
Remount the air flow sensor as shown in the picture.
The carrier plate must be located on the right as when looking in flow direction, since
otherwise measuring errors will occur.
A foul or blackened air flow sensor is an indication of some disorder in the building
installations (for ex. negative pressure) or insufficient cleaning or servicing, but nonetheless
requires replacement. Correct the disorder in the building installations prior to replacement.
To dismount air flow sensor
release carrier plate fastening
screws here at the suction pipe.
Only dismount air flow sensor
from suction pipe while
fastened to the carrier plate.
Carrier plate
Air flow sensor
(galvanised)
Air flow sensor
(green board)
4-pole plug for air flow
sensor
(white)
71


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Wodtke Frank Airplus S4 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Wodtke Frank Airplus S4 in the language / languages: English as an attachment in your email.

The manual is 3.18 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Wodtke Frank Airplus S4

Wodtke Frank Airplus S4 User Manual - German - 76 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info