10 Fire Safety Regulations
Attention:
All flammable components, furniture or furnishing
fabrics, for example, in the immediate vicinity of
the furnace must be protected against the effects
of heat. In particular, the applicable local fire safety
regulations and provisions must be observed.
The following fire safety clearances must be
maintained at minimum:
Di-
men-
sion
Value
Explanation
A
80
cm
Minimum distance in radiation
area / to hot air outlets
B
40
cm
Minimum distance in radiation
area / to hot air outlets with
ventilated radiation protection
Di-
men-
sion
Value
Explanation
C
20
cm
or
15
cm
Minimum clearance outside the
radiation area and outside the
area of hot air outlets:
to the rear: 20 cm
to the sides: 15 cm
D
Minimum clearance of flue pipe
to flammable components ac-
cording to specifications of the
flue pipe manufacturer
E
5 cm
Minimum clearance of flue pipe
to rear furnace wall.
F
20
cm
Minimum thickness of non-flam-
mable, dimensionally stable
thermal insulation in the perime-
ter of the flue pipe or clearance
of a protective tube to the flue
pipe in case of lead-through in a
wall with flammable components
No
Fig.
100
cm
A minimum clearance to compo-
nents / objects to be protected of
100 cm is required above the
furnace.
Example with connector piece to chimney
within the installation room
Fig. 55: fire safety clearances
Example with connector piece through wall with
flammable components to chimney
Fireproof
surface /
floor plate
Connector piece
Clearance
E
Ventilated radiation protection
30


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Wodtke Family.nrg at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Wodtke Family.nrg in the language / languages: English as an attachment in your email.

The manual is 6.01 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Wodtke Family.nrg

Wodtke Family.nrg Usermanual and installation guide - German - 72 pages

Wodtke Family.nrg User Manual - French - 72 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info