The rear wall of the furnace does not become hot.
No minimum distance must be maintained for fire
safety reasons. Nevertheless, we strongly recom-
mend maintaining a distance of 20 cm to the rear
(e.g. for maintenance work) in order to ensure ac-
cessibility.
Floors made of flammable material, such as car-
pet, parquet flooring or cork, must be replaced or
protected by a surface of non-flammable materi-
als, such as ceramic, stone, glass or a floor plate
made of steel, under the furnace as well as in front
of the combustion chamber opening at least 50 cm
to the front and at least 30 cm to the sides beyond
the furnace opening (not the outside edge of the
unit, but rather the inside edge of the combustion
chamber opening).
No additional thermal insulation is required
underneath the furnace; a load-bearing and
fire-safe surface is sufficient, as there is no
downward heat emission. All air intake and outlet
openings must be kept completely free and may
not be blocked or covered: danger of the furnace
overheating!
The minimum clearance between the hot flue
pipe (connection piece to the chimney) and
components to be protected must be designed
according to the the specifications of the
manufacturer of the flue pipe (Dimension D).
If the flue pipe is not connected directly
horizontally as recommended, but rather led
vertically behind the furnace, the vertical part of
the flue pipe must have a minimum clearance of
5 cm to the rear wall of the furnace (dimension
E) .
If the flue pipe is run through a wall with flammable
components to the chimney, either a non-
flammable, dimensionally stable thermal
insulation is required in a perimeter of 20 cm to
the flue pipe, or a protective tube at a distance of
20 cm to the flue pipe is required (Maß F).
11 Approved Fuels
According to the 1st Federal Immission Control
Act (1st BImSchV), only natural wood pellets are
permitted. Cut firewood or other burnable or waste
materials may never be used.
Only pellets which have been certified accord-
ing to ENplus-A1, DINplus or DIN EN 14961-2
Class A1 may be used in wodtke Pellet-
Primärofen units. Wood pellets with an ash
content of > 0.7% may also not be used, as oth-
erwise the cleaning and maintenance expense
is too high. Be sure to observe the notices re-
garding pellet quality in Chapter 3.8!
Cut firewood or other burnable or waste mate-
rials may never be used. Other fuels also lead
to damage to the wodtke Pellet Primärofen and
burden our environment.
If the furnace is not operated with approved
fuels, any warranty or guarantee claims are
void and dangerous operating conditions may
result. Do not perform any experiments.
A pellet diameter between 5 and 8 mm is per-
mitted
3
. The length of the pellets should not ex-
ceed 30 mm. Pellets with high dust content (>5%)
should likewise not be used.
3
The recommended pellet diameter is 6 mm; in case of devia-
tions, the fuel throughput may need to be adjusted. The same also
applies for differing lengths.
31


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Wodtke Easy.nrg S5 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Wodtke Easy.nrg S5 in the language / languages: English as an attachment in your email.

The manual is 6.01 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Wodtke Easy.nrg S5

Wodtke Easy.nrg S5 User Manual - German - 68 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info