7 Placement of the Furnace
Please observe the specifications on fire protec-
tion regulations in Chapter 10.
The furnace must be installed on a sufficiently
load-bearing and non-flammable base. At least 20
cm of free space must be available to the rear and
sides of the furnace after installation for assembly
work.
Adjust the feet of the furnace to 25 mm floor clear-
ance to the bottom edge of the panelling at the in-
stallation location so that sufficient convection air
can flow in from below / laterally below (see Fig.
2).
8 Electrical Connection / Ca-
bling
The power plug must be disconnected before
performing electrical work on the unit!
Electrical connections on the unit must be made
by a qualified specialist in accordance with appli-
cable local technical rules, particularly the VDE
guidelines. No liability is accepted for damage to
the unit due to improper connections, and any war-
ranty is void.
No electrical connection cables from and to the
unit may contact hot exterior surfaces of the fur-
nace or of the flue pipe. The installation may not
be made over sharp edges, corners, etc. All elec-
trical connections are located on the main board
of the furnace.
The rear bottom panel and the left side panel or
the front bottom panel of the furnace may have to
be removed for the electrical connection, depend-
ing on the desired connection (for removal of outer
panelling, see Chapter 6). The connection lines
can be installed from below through the floor (hid-
den installation) or above the floor (see diagram
below).
The guard covering over the main board may not
be removed for the external electrical connection
(this covering protects the main board from soot
and dirt and is only removed when replacing com-
ponents)! The furnace may only be operated with
this cover in place!
Fig. 28: connection diagram
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Wodtke Easy.nrg S5 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Wodtke Easy.nrg S5 in the language / languages: English as an attachment in your email.

The manual is 6.01 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Wodtke Easy.nrg S5

Wodtke Easy.nrg S5 User Manual - German - 68 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info