5.12.4 Modulation heating programme via external controller (continuous
controller)
= display shows HE for continuous output modulation via external controller
= display shows flashing dot for feed screw operation
= display shows thermal output in kW
The Modulation input permits infinite adjustment of thermal output. For this purpose an external
controller (such as a heating controller) with a signal output of 0-10 V or 4-20 mA must be
used.
The signal voltage or current corresponds to the thermal output
shown on the display. The appliance will deliver thermal output as
required by the external controller.
In the case of external modulation the external controller will usually have two outputs, of which
one switches the device “ON” and “OFF” via the “ON/OFF” input, while the other controls the
stove’s thermal output via the “MODULATION” input.
Note:
Only use potential-free controllers for the “ON/OFF” input.
The “MODULATION” input requires a controller with a signal output of 0-10 V or 4-20 mA.
It first has to be activated and adapted to the controller’s signalling mode (0-10V voltage
or 4-20 mA current) (see assembly instructions). A 0V or 4 mA signal at the “MODULATION”
input means minimum thermal output, while a 10V or 20 mA signal means maximum thermal
output.
With the +/- keys you can change the previously set output level in 0.5 kW steps at any time.
However, manual changes in thermal output only become effective when the “MODULATION”
input has been deactivated again.
Display indicates
external modulation
(continuous)
H
E
4.5
23


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Wodtke CW 21 Airplus S4 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Wodtke CW 21 Airplus S4 in the language / languages: English as an attachment in your email.

The manual is 3.18 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Wodtke CW 21 Airplus S4

Wodtke CW 21 Airplus S4 User Manual - German - 83 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info