Mains voltage tolerance range 230V +6 % and -10 %,
Mains voltage interruption < 50ms: no interruption of function
Water supply
(Constant water supply
optional)
3/8 inch hose connector with main valve, and filter with 0.2 to
0.25mm mesh size, on site.
Min. 0.2MPa flow pressure at 2l/min., max. 0.6MPa.
Water temperature max. 35°C.
The set of hoses provided with the new coffee machine and/or
the new water filter must be used. Do not use old hoses.
Water quality For drinking water with carbonate hardness above 5 °dkH aWMF
water filter should be installed upstream.
Water drain pipe Hose amin. DN 19, minimum downward slope of 2cm/m
Ambient temperature +5°C to max. +35°C (empty the water line in case of frost).
Maximum humidity 80 % relative humidity without condensation.
Do not use unit outdoors.
Degree of protection IP X0
Installing surface The unit must be placed on alevel, flat, and sturdy surface.
The unit is not intended to be located on asurface that is sprayed
or cleaned with awater hose, steam jets, steam cleaner, or similar
devices.
Installation clearances For operating, service and safety reasons the machine should be
installed with aclearance of not less than 50mm at the back and
sides from the building or non-WMF components. A clear height
of 1,100mm from the top of the supporting surface should be
ensured. The height of the installation surface above the floor
is at least 850mm. If the machine connections are to be run
downwards through the counter, please make space for the lines,
which can reduce the usable space below the machine.
Installation dimensions of the
water filter
See the User Manual for the water filter.
These specifications for the electrical connection and the standards quoted apply for connecting the
machine in EU countries. It may be necessary to also observe additional country-specific regulations.
Outside the EU countries acceptance of the standards quoted is to be checked by the legal entity or
natural person who wishes to use the machine.
The local power supply must be constructed according to IEC 364. To improve safety, the coffee machine should be
fitted with an FI 30mA earth leakage current circuit breaker complying with EN61008. Near the device or about 30cm
below the counter top there should be ashockproof socket as asingle-phase connection installed locally on the rear
or side wall of the counter substructure or acountry-specific single-phase socket. If the mains cable for this device is
damaged then it must be replaced by our service personnel or asimilarly qualified person, in order to prevent hazards.
A separator switch is recommended for aflexible connection. The mains cable must not come into contact with hot
surfaces. The mains switch and plug top are part of the customers on-site installation. The machine may not be fitted
with afixed permanent mains connection if installed on atransporting trolley (a mobile station).
In order to avoid possible faults from arising on our shielded data lines due to potential equalization currents
between the devices, an additional potential equalization unit should be planned for devices connected to the
vending system. (See EN 60309)
67


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Wmf Presto at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Wmf Presto in the language / languages: English as an attachment in your email.

The manual is 1,48 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Wmf Presto

Wmf Presto User Manual - German - 72 pages

Wmf Presto User Manual - Dutch - 68 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info