6 Conditions for Installation and Operation
The machine operator must arrange for the site preparatory work. This should be carried out by
approved contractors in accordance with general and local regulations. WMF customer service
technicians are only permitted to connect up the machine to the prepared connections. They are
not authorised to carry out plumbing or wiring work on site and will not be responsible for such
work!
Rated power 3.3 kW
Connecting cable, site supply*
3 x 1.5
2
Fuse, site supply
1 x 16 A
Mains voltage tolerance
230 V + 6 % - 10 %
Power cut < 50 ms does not affect machine operation
Water supply line
TW 15 (min. DN 6 or 1/4") with main shutoff valve
and dirt filter installed by customer, 0,2 MPa flow
pressure at 2 l/min, max. 0,6 MPa
Water quality
If the local water has a carbonate hardness over 5° a
WMF water filter must be fitted in the supply line.
Water drain line
Hose, DN 19, minimum gradient 2 cm/m
Ambient temperature
+ 5°C to + 35°C (drain water system in case of frost)
Max. humidity
80 % rel. humidity without dewing. Do not spray
machine with water. Do not use machine out of
doors!
Installation clearance
For operating, service and safety reasons the machine
should be installed with clearance of not less than 50
mm from the back and sides from the building or non-
WMF components.
A clear height of 1100 mm from the top of the
supporting surface should be ensured. The height of
the supporting surface from the floor surface should be
not less than
700 mm and not more than 900 mm.
If the machine connections are to be routed down
through the counter, remember to also allow space for
the connections. These may restrict the available space
below the machine.
Water filter installation dimensions
W x H x D
Standard: 250 x 500 x 400 mm
Jumbo: 290 x 670 x 420 mm
* The on-site electrical system must comply with IEC 364. An e.l.c.b. switch with 30 mA rated fault current to
EN 61008 should be installed upstream of the unit for increased safety. An earthed socket outlet must be installed
near the unit for one-phase connection. A 5-pole CEE/CEKON socket outlet to EN 60309 must be installed for
three-phase connection. If the mains power cable of this unit is damaged, it must be replaced by our customer
service engineer or a similarly qualified person. If the machine is permanently connected on site, a disconnecting
device (master switch) to EN 60947 acting on all poles and with a contact gap of at least 3 mm must be installed
upstream. The disconnecting device is also recommended for flexible connection. The mains power cable must not
be allowed to come into contact with hot parts of the machine. Master switch and socket outlet are part of the on-
site installation. The machine must not be installed with permanent on-site connection when mounted on a trolley.
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Wmf BISTRO easy Series 8300 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Wmf BISTRO easy Series 8300 in the language / languages: English as an attachment in your email.

The manual is 1,63 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info