WIKING Nordic 7
WIKING Nordic 9
WIKING Nordic 9G WIKING Nordic 10G
Wood-burning stoves weight 95 kg 93 kg 95 kg
The wood-burning stove’s di-
mensions
(height x width x depth)
894 x 527 x 426 mm 894 x 527 x 431 mm 1014 x 527 x 431 mm
Distance to furniture - front 800 mm 800 mm 800 mm
The stove is mainly made of sheet iron.
Connection to the chimney
The stove has a smoke outlet at the top and at the back. It can be installed with an approved smoke pipe
and a steel chimney, or connected to a brick chimney with a fullform smoke pipe.
Make sure that the chimney is tight and that no false draft is caused around neither the cover plate, in
connection with a covered smoke outlet, nor the cleanout door and pipe connections. Please note that
bent and/or horizontal smoke pipes will reduce the effect of the chimney draft.
Changing the smoke outlet from top outlet to rear outlet
(WIKING Nordic 9G/WIKING Nordic 10G)
1. Lift the stove top plate off.
2. There is a cut-out in the rear plate for the smoke outlet. Break off the plate within this cut-out to make
a hole in the rear plate so there is room for the smoke outlet.
3. Remove the cover plate on the back of the stove by removing the three screws (Torx Bit no. 30). Be
careful not to lose the screws behind the welded rear plate.
4. Remove the three screws. Lift the ue ring off the top of the stove.
5. Mount the cover plate on the top of the combustion chamber using the three screws (Torx bit no. 30).
6. Insert the ue ring into the smoke outlet hole in the rear of the stove and secure it with the three
screws.
7. Replace the stove top plate.
Installing soapstone in the heat compartment (WIKING Nordic 10G)
1. Lift the stove top plate off.
2. Place soapstone slabs in the heat storage compartment making sure that the hole in every slab is
right above the smoke ring.
3. Replace the stove top plate.
Requirements for chimney and smoke pipe
The stove requires a draft of at least 12 Pa.
The chimney must be of a proper height to ensure that the draft is sufcient and that smoke does not
become bothersome. If the chimney is so high that it cannot be cleaned from the top, an easily acces-
sible cleaning hatch must be installed. We recommend that you always contact your local chimney sweep
before purchasing a chimney.
Minimum clearance: Ø150 mm, which corresponds to your WIKING wood-burning stove’s exhaust pipe.
22


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Wiking Nordic at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Wiking Nordic in the language / languages: English, German as an attachment in your email.

The manual is 1,03 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Wiking Nordic

Wiking Nordic Usermanual and installation guide - Dutch, French - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info