WATER DRAINAGE INSTRUCTIONS
Using a portable dehumidifier requires that collected water be emptied frequently. Draining water from this unit
can be done in 3 different methods:
1. DRAIN BUCKET METHOD
NOTES:
1. The drain bucket can hold up to 14 pints of water. When the buck-
et is full, the Full indicator light will light. The compressor and fan will
turn off, the Full indicator will light, and a P2 code will be displayed.
2. It is recommended to turn the unit off before removing the drain
bucket.
3. Grip the left and right handles of the drain bucket securely and
carefully pull out the drain bucket. Do not put the drain bucket on the
floor because the bottom of the bucket is not even which may cause
the water to spill. See Fig.5 and Fig.6.
4. Remove the water from the drain bucket and replace it back to the
dehumidifier. The drain bucket must be installed properly and se-
curely seated for the dehumidifier to operate.
5. The machine will restart when the drain bucket is restored in its
correct position. If the unit was turned off prior to the removal of the
drain bucket, press the Power button to restore operation.
When you remove the drain bucket, do not touch any inside parts of
the unit. Doing so may damage the product and result to injury.
Be sure to push the drain bucket gently all the way into the unit.
Banging the bucket against anything or failing to push it in securely
may cause the unit not to operate.
If the pump filter drops when you remove the bucket (see Fig.7), you
must reinstall the pump filter properly to the unit before replacing the
drain bucket into the unit (see Fig.8).
Upon replacing the bucket, firmly push the bucket in place until it
locks. There should be no gaps between the bucket and the dehu-
midifier.
When the drain bucket is removed, the unit will beep 8 times and the
digital display shows Eb. Eb is an error code that indicates that
the drain bucket is removed or not positioned correctly. Make sure
that the drain bucket is properly installed and the in right position.
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Whynter RPD-501WP at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Whynter RPD-501WP in the language / languages: English as an attachment in your email.

The manual is 1,71 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info