727507
14
Zoom out
Zoom in
Previous page
1/22
Next page
14
TURBO FUNCTION
Turbo function will be helpful to cool or heat your room quickly and effectively by operating at the maximum fan
speed.
NOTE: Turbo function is only available in Cool and Heat mode.
LOUVER ANGLE MEMORY FUNCTION
Power failure during operation or pressing the ON/OFF button on the remote control will stop the unit completely.
When the power restores or pressing the ON/OFF button on the remote control again, the unit restarts automatically
with the previous open angle of the horizontal louver by the louver angle memory function. Press the AUTO/COOL
manual button (on the indoor unit) and the open angle of the horizontal louver will be restored to the standard angle.
NOTE: It is highly recommend that the open angle of the horizontal louver should not be set too small, in
case the condensed water forms and drops from the horizontal louver.
FOLLOW ME FUNCTION
The remote control serves as a remote thermostat allowing for the precise and comfortable temperature control.
With this technology, an efficient temperature sensor is integrated in the remote control. To activate the Follow me
function, press Follow Me button on the remote control. Once this function is activated, the remote control will send
the temperature signal to the air conditioner every 3 minutes interval until you press the Follow Me button again. The
air conditioner will automatically cancel the Follow Me feature if it does not receive the signal during any 7 minutes
interval.
NOTE: The Follow Me feature is not available in DRY and FAN mode. Shifting the operating mode or turning
off the unit will cancel the Follow Me feature automatically. The remote control needs to be within 26 feet reach of
the indoor unit for the Follow Me mode to work appropriately.
SELF-CLEAN FUNCTION
Self Clean function will prevent growth of harmful micro-organisms by eliminating the moisture inside of the indoor
unit. In this function, the indoor unit will run in fan mode for 11 minutes. Once the time has elapsed, a low heat oper-
ation will run for 1 minute and will then switch to fan mode for another 2 minutes. The appliance will automatically
shut-off once the cycle completes.
NOTE: It is recommended the use the Self Clean function every 15 days. In high humidity environment, use it in
a weekly basis. This will prevent rusting of the air conditioner’s evaporator coil.
SILENCE FUNCTION
Press the “Silence” button on the remote control to initiate Silence function. When the Silence function is activated,
the compressor will run at a low frequency rate and the indoor unit will bring faint breeze, which will reduce the noise
to the lowest level and create a quiet and comfortable environment.
LOW TEMPERATURE HEATING (FP mode)
The FP (Freezing Protection) mode is designed to run at ambient temperature as low as 46°F / 8°C, which keeps the
room temperature at a comfortable level during the winter season.
NOTE: This unit uses heat pump for heating and the heating mode does not work when temperature is be-
low 45°F.
REFRIGERANT LEAKAGE DETECTION
With this safety feature, the indoor unit will display “EC” when it detects a refrigerant leakage.
ANTI-COLD AIR FUNCTION
The unit is designed not to blow cold air on HEAT mode when the indoor heat exchanger is in one of the following
three situations and the set temperature has not been reached.
A) When heating has just started
B) Defrosting
C) Low temperature heating
To prevent cold air flow, the indoor unit’s fan will stop if the indoor coil temperature is lower than 62°F(17°C). The fan
operation will resume once the indoor coil’s temperature is higher than 88F.
SPECIAL FUNCTION FEATURES
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Whynter MSFS-024H23016-01NE at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Whynter MSFS-024H23016-01NE in the language / languages: English as an attachment in your email.

The manual is 3,66 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info