TROUBLESHOOTING
Problem
Possible Causes
Solutions
The portable air
conditioner does not
turn on
Power failure / outage.
The automatic switch, line
fuse, or breaker has been
tripped.
The power supply voltage is
too low.
The power cord is damaged.
The L.C.D.I. power plug for the
unit is tripped.
The internal water reservoir is
full and „P1” appears on
display.
Restore the power supply.
Flip the switch / change the fuse / turn the
breaker back on. Also note that you may have
too many appliances drawing power on one
circuit, you may need to move the other
appliances to another circuit.
Move the unit onto another circuit with the
correct voltage.
Call for service. Only authorized personnel
should replace damaged power cord or power
plug.
Press the Reset button on the L.C.D.I. power
plug.
Drain water from the air conditioner.
The unit turns on but
the compressor does
not turn on (the fan
runs but the unit is not
cooling)
The room temperature is
outside of the operational
tolerances of the unit.
The Cooling mode is not on.
The compressor has not
turned on yet because of its
time delay.
The set temperature is too
high.
The internal water reservoir is
full and „P1” appears on
display.
This unit is designed to work in ambient
temperatures of 63°F to 90°F.
Press the MODE button until the COOL light
is shown on the display.
Give the compressor 3 minutes to turn on
after the Cooling mode has been selected.
Set the air conditioner to a lower temperature.
It is recommended to set the temperature to
at least 5°F of the ambient temperature.
Either manually drain the water by removing
the drain plug or allow the unit to exhaust the
water itself by running the fan only mode.
Then cooling will resume.
The air coming out of
the unit is not very
cold, or the airflow
volume is weak
The filters are dirty or
obstructed.
The air intake or exhaust is
obstructed.
The unit is set in DRY or FAN
mode.
Clean the air filters.
Make sure there is at least 20" of clearance
from the air intake. Make the length of the
exhaust hose is as short as possible.
Set the unit to the cooling mode.
Downloaded from www.Manualslib.com manuals search engine
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Whynter ARC-10WB at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Whynter ARC-10WB in the language / languages: English as an attachment in your email.

The manual is 0,76 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info