Type of gas used
marking
Rated thermal
flow rate
Rated
consumption
Reduced heat
capacity
Gas pressure
mbar
.xam.tar.nimWkWk
II2H3+
IT - ES - GR - PT
- AE - MA - TN -
DZ
NATURAL GAS
(Methane)
G20
2 Ring
Rapid
Semi-rapid
Auxiliary
168
125A
97A
78A
4.80
3.00
1.75
1.00
457 l/h
586 l/h
167 l/h
95 l/h
2.20
0.60
0.35
0.30
17 20 25
LIQUEFIED
PETROLEUM GAS
(Butane)
G30
2 Ring
Rapid
101
85A
4.30
3.00
313 g/h
218 g/h
1.90
0.60
20 28-3035
Semi-rapid66A 1.75 127 g/h 0.35
Auxiliary501.0073 g/h 0.30
LIQUEFIED
PETROLEUM GAS
(Propane)
G31
2 Ring
Rapid
101
85A
4.30
3.00
307 g/h
214 g/h
1.90
0.60
25 37 45
Semi-rapid66A 1.75 125 g/h 0.35
Auxiliary501.0071 g/h 0.30
II2H3B/P
RU - SK - CZ -
UA - RO - BG -
HR - SI - RS
NATURAL GAS
(Methane)
G20
2 Ring
Rapid
168
125A
4.80
3.00
457 l/h
286 l/h
2.20
0.60
17 20 25
Semi-rapid 97A1.75167 l/h 0.35
Auxiliary78A 1.00 95 l/h 0.30
LIQUEFIED
PETROLEUM GAS
(Butane)
G30
(Propane)
G31
2 Ring
Rapid
101
85A
4.80
3.00
313 g/h
218 g/h
1.90
0.60
25 30 35
Semi-rapid66A 1.75 127 g/h 0.35
Auxiliary501.0073 g/h 0.30
II2HS3B/P
HU*
NATURAL GAS
(Methane)
G20
2 Ring
Rapid
158B
119
4.80
3.00
457 l/h
286 l/h
2.35
0.70
20 25 33
Semi-rapid 92A1.75167 l/h 0.40
Auxiliary741.0095 l/h 0.35
NATURAL GAS
G25.1
2 Ring
Rapid
175B
135
4.80
3.00
531 l/h
332 l/h
2.20
0.60
18 25 33
Semi-rapid100A1.75194 l/h0.35
Auxiliary811.00111 l/h 0.30
LIQUEFIED
PETROLEUM GAS
(Butane)
G30
(Propane)
G31
2 Ring
Rapid
101
85A
4.30
3.00
313 g/h
218 g/h
1.90
0.60
20 30 35
Semi-rapid66A 1.75 127 g/h 0.35
Auxiliary501.0
073 g/h 0.30
Type of gas used
flow rate (kW)
Total rated
consumption
Air required (m
3
) for
burning1m
3
of gas
II2H3+
IT - ES - GR -
PT - AE - MA -
TN - DZ
G20
20 mbar2C - 1 R - 2 SR - 1 AUX 12.301172 l/h9.52
G30
28-30 mbar2C - 1 R - 2 SR - 1 AUX 11.80858 g/h 30.94
G31
37 mbar2C - 1 R - 2 SR - 1 AUX 11.80842 g/h 23.80
II2H3B/P
RU - SK - CZ -
UA - RO - BG -
HR - SI- SR
G20
20 mbar2C - 1 R - 2 SR - 1 AUX 12.301172 l/h9.52
G30/G31
30 mbar2C - 1 R - 2 SR - 1 AUX 11.80858 g/h 30.94
II2HS3B/P
HU*
G20
25 mbar2C - 1 R - 2 SR - 1 AUX 12.301172 l/h9.52
G25.1
25 mbar2C - 1 R - 2 SR - 1 AUX12.30 1362 l/h 8.187
G30/G31
30 mbar2C - 1 R - 2 SR - 1 AUX 11.80858 g/h 30.95
* if the appliance is intended to be in use in Hungary, injectors already assembled (G20 - 20mbar) must be replaced according to Hungarian market regluation,
available in Instruction for User. Injectors for replacement are available in the kit. Please refer to User Manual information. Injector replacement must be done
by a qualied technician.
ELECTRIC SUPPLY: 220-240 V ~ 50/60 Hz - 0,6 W
Type of burner Injector
Rated thermal Model configuration