515836
19
Zoom out
Zoom in
Previous page
1/21
Next page
CAUTION:
1. Use an individual power circuit specifically for the air conditioner. As for the wiring method, refer to the
circuit diagram on the inside of the access door .
2. Check that the cable thickness conforms to the power source specification.
3. Check the wires and make sure that they are all tightly fastened after cable connection.
4. Be sure to install an earth leakage circuit breaker in a wet or moist area.
Cable Specifications
WIRING DIAGRAM
Make sure that the colour of wires of the outdoor
unit and the terminal number are the same as
those of the indoor unit.
Power supply from Indoor unit, including
7K, 9K, 12K Model
Power supply from Indoor unit, including
18K, 22K Model
Defrost Cable (for heat-pump air
conditioner only, and it's an optional part)
Defrost cable (for heat-pump models only)
After connection, the defrost wire should be
well wrapped with a wrapping tape and the
connector should be put inside the unit.
Capacity
(Btu/h)
Power cord
Power connecting
cord
Power connecting
cord 1
Main
power
supply
(Note)
Ty p e
Normal cross -
sectional area
Ty p e
Normal
cross -
sectional
area
Ty p e
Normal
cross -
sectional
area
7K, 9K,
12K
H05VV-F 1.0~1.5mm² X3 H07RN-F 1.0mm² X3 H05RN-F
0.75mm² X2
(Heat-pump)
To indoor
18K, 22K
H05VV-F
RVV
1.5~2.0mm² X3 H07RN-F 1.5mm² X3 H05RN-F
0.75mm² X2
(Heat-pump)
To indoor
AC L-IN
AC N-IN
1(N)
2(L)
1(N)
3(SI)
2(L)
3(SI)
HEAT PUMP
Power connecting cord
Indoor unit
Te r m i n a l
Outdoor unit
Te r m i n a l
Yellow/Green
Blue (Gray)
Brown
Black
Yellow/Green
Blue (Gray)
Brown
Black
Evaporator
Indoor unit control board
Power supply
YE/GN
BN
BU
HEAT PUMP
Power connecting cord 1
Power connecting cord
Indoor unit
Te r m i n a l
Outdoor unit
Te r m i n a l
Brown
Blue
Brown
Blue
Brown
Blue
Brown
Blue
Yellow/Green
Yellow/Green
Defrost wire
(indoor)
Defrost wire
(outdoor)
22
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Whirlpool AMD 322 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Whirlpool AMD 322 in the language / languages: English as an attachment in your email.

The manual is 1,79 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info