CHECKS AND TEST RUN AFTER
INSTALLATION
Check Items After Installation
Test Run
1. Preparation of Test Run
Do not switch on the power before all installation work is completed.
Confirm that the control line is correctly installed and all electrical lines are securely connected.
Open the shutoff valves of the large and small pipes.
Clear the unit of any foreign bodies, especially metal scraps, line ends and tools.
2. Test Run (Fig. 2 page 128)
Plug in, press the “ON/OFF” key on the remote control, and the air-conditioning unit should start.
Press the Mode key, select the operating modes such as cooling and fan, and check for normal operation.
ELECTRIC HEATING BELT
Check items Problems caused to improper installation
Is the installation secure? The unit may fall, vibrate or make noise
Has gas leakage been checked? May cause unsatisfactory cooling (heating) effect
Is the thermal insulation of the unit sufficient? May cause unsatisfactory cooling (heating) effect
Is drainage smooth? May cause condensation and dripping
Is the main supply voltage the same as the
rated voltage specified on the nameplate?
The unit may break down or components may burn out
Are the lines and pipelines correctly installed? The unit may break down or components may burn out
Has the unit been safely grounded? Risk of electrical leakage
Are the models of lines in conformity with
requirements?
The unit may break down or components may burn out
Are there any obstacles near the air inlet and
outlet of the indoor and outdoor units?
May cause unsatisfactory cooling (heating) effect
Have the length of refrigerating pipe and
refrigerant charge amount been recorded?
It is difficult to know how much refrigerant to use
ELECTRIC HEATING BELT FOR INVERTER MODEL
AMC 996, AMC 998 ONLY
In case of malfunction of the outdoor temperature sensor, both
electric belts stop working. Under normal conditions,
operations is as follows:
1.
When the outdoor temperature is -5° or less and the
compressor does not start, the electric heating belt on the
compressor start; if the compressor is running or does not
start but the outdoor temperature is > -2°C, the electric
heating belt does not start. If the compressor does not start
and the outdoor temperature is between -5°C and -2°C the
electric heating belt on the compressor maintains its current
status.
2.
When the outdoor temperature is less or equal to 3°C the
electric condenser heating belt will work. If the outdoor
temperature is greater than 6°C it will not work. Between
3° and 6°C it maintains its current status.
Electric heating belt
25


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Whirlpool AMC 998 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Whirlpool AMC 998 in the language / languages: English as an attachment in your email.

The manual is 1,91 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Whirlpool AMC 998

Whirlpool AMC 998 User Manual - German - 25 pages

Whirlpool AMC 998 User Manual - Dutch - 25 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info