SPECIFICATIONS AND TECHNICAL DATA
(DEPENDING ON THE MODEL)
1.
The above data may change without notice. The data on the rating are accurate.
2.
When the unit is started again after a stop, it automatically resumes in the same mode as when it was
stopped. The outdoor unit starts after a slight delay.
Working temperature range:
Model AMC 996 AMC 998
Functions
Cool/Heat Cool/Heat
Cooling capacity (W)
2638 (1452~3441) 3710 (1935~3925)
Heating capacity (W)
2784 (1882~3817) 4140 (2151~4409)
Rated Voltage
220-240V~ 220-240V~
Rated Frequency
50Hz 50Hz
Cooling/Heating rated current 3.17/3.48A 4.83/5.11A
Maximum input current 6.1A 6.4A
Cooling/Heating rated power 755/819W 1134/1259W
Energy efficiency ratio 3.56/3.65A 3.4/3.41A
Energy Class A/A A/B
Air circulation volume (m3/h) 450 550
Refrigerant and weight R410A 1.25Kg R410A 1.25Kg
Moisture Protection Class IPX4 IPX4
Noise (Indoor/Outdoor) dB(A) 35/52 37/52
Climate type T1 T1
Anti-electric shock protection 1 I
Weight (kg) Indoor unit/
Outdoor unit
11/45 11/45
Dimensions (cm)
WxHxD
Indoor unit 830x285x189
Outdoor
unit
848x540x320
Model AMC 993 AMC 994
Functions
Cool/Heat Cool/Heat
Cooling capacity (W)
5275 6741
Heating capacity (W)
5862 7474
Rated Voltage
220-240V~ 220-240V~
Rated Frequency
50Hz 50Hz
Cooling/Heating rated current 7.98/7.36A 10.25/10.57A
Cooling/Heating rated power 1813/1673W 2357/2431W
Max. Power Input 2400 3500
Energy efficiency ratio 3.06/3.67A 3.06/3.21A
Energy Class B/A B/C
Air circulation volume (m3/h) 840 930
Refrigerant and weight R410A 1.7Kg R410A 2.35Kg
Noise (Indoor/Outdoor) dB(A) 44/55 46/55
Climate type T1 T1
Moisture Protection Class IPX4 IPX4
Anti-electric shock protection 1 I
Weight (kg) Indoor unit/
Outdoor unit
13/45 13/75
Dimensions (cm)
WxHxD
Indoor unit 1020x310x228 1020x310x228
Outdoor
unit
848x592x320 950x840x412
Model AMC 990 AMC 991 AMC 992
Functions
Cool/Heat Cool/Heat Cool/Heat
Cooling capacity (W)
2257 2689 3664
Heating capacity (W)
2257 2843 3957
Rated voltage
220-240V~ 220-240V~ 220-240V~
Rated frequency
50Hz 50Hz 50Hz
Cooling/Heating rated current 2.98/2.89A 3.87/3.59A 4.79/5.17A
Cooling/Heating rated power (W) 676/654 876/814 1122/1171
Energy efficiency ratio 3.35/3.61 3.35/3.69 3.41/3.45
Energy class A/A A/A A/B
Air circulation volume (m3/h) 422 422 479
Refrigerant and weight R410A 0.95Kg R410A 1.0Kg R410A 1.2Kg
Noise (Indoor/Outdoor) dB(A) 33/50 33/50 37/54
Climate type T1 T1 T1
Moisture Protection Class IPX4 IPX4 IPX4
Anti-electric shock protection 1 1 1
Weight (kg) Indoor unit/Outdoor unit 11/25 11/30 11/40
Dimensions (cm)
WxHxD
Indoor unit 830x285x189 830x285x189 830x285x189
Outdoor unit 660x428x255 848x540x320 848x540x320
Working temperature range AMC 996, AMC 998
Inside Temp
DB/WB (°C)
Outside Temp
DB/WB (°C)
Maximum cooling 32/23 43/26
Minimum cooling 21/15 21/-
Maximum heating 27/- 24/18
Minimum heating 20/- -10/-
32602005GB.fm Page 32 Thursday, December 14, 2006 11:24 AM
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Whirlpool AMC 991 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Whirlpool AMC 991 in the language / languages: English as an attachment in your email.

The manual is 4,3 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Whirlpool AMC 991

Whirlpool AMC 991 User Manual - German - 25 pages

Whirlpool AMC 991 User Manual - Dutch - 25 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info