NOTE: the power supply cable must be long enough to permit its upward extraction.
To secure the hob, use the brackets (A) provided with it. Fit the brackets into the relevant bores shown by the arrow and fasten them by means of their screws
in accordance with the thickness of the worktop (see the following gures).
20
30
60
40
Top 20 mm Top 40 mm
Top 30 mm Top 60 mm
NO
ADJUSTMENT TO DIFFERENT TYPES OF GAS
WARNING
This operation must be performed by a qualied technician.
If the appliance is intended to operate with a different gas from the gas type stated on the rating plate and information label on the top of the hob, change the
injectors.
Remove the information label and keep it with the instructions booklet.
Use pressure regulators suitable for the gas pressure indicated in the Instruction:
the gas injector must be changed by After Sales Service or a qualied technician;
injector not supplied with the appliance must be ordered from After Sales Service;
adjust the minimum setting of the taps.
NOTE: when liquid petroleum gas is used (G30/G31), the minimum gas setting screw must be tightened as far as it will go.
IMPORTANT: should you experience difculty in turning the burners knobs, please contact the After Sales Service for the replacement of the burner
tap if found to be faulty.
IMPORTANT: when gas cylinder is adopted, the gas cylinder or gas container must be properly settled (vertical orientation).
REPLACING THE INJECTORS (see the injector table in the Instruction)
Remove grids (A).
Extract burners (B).
Using a socket spanner of the appropriate size unscrew the injector (C), unscrew the injector
to be replaced.
Replace it with the injector suitable for the new type of gas.
Re-assemble the injector in (D).
If you have a multiple crown burner use side spanner to replace the injector (E).
Before installing the hob, remember to afx the gas calibration plate supplied with the injectors in
such a way that it covers the existing information relating to gas calibration.
ADJUSTING MINIMUM GAS SETTING OF TAPS
To ensure that the minimum setting is correctly adjusted, remove the knob and proceed as follows:
tighten screw to reduce the ame height (-);
loosen screw to increase the ame height (+).
The adjustment must be performed with the tap in minimum gas setting position (small ame) :
the primary air of the burners does not need to be adjusted;
at this stage, light up the burners and turn the knobs from max position to minimum position
to check ame stability.
Upon completion of adjustment, reseal using sealing wax or an equivalent material.
REFERENCE TO LOCAL REGULATIONS
FR
The installation and maintenance of the appliance must be carried out by a qualied skilled technician in accordance with the regulations in force, and in particular:
Decree of 2 August 1977
Technical and Safety Rules applicable to fuel gas and liqueed hydrocarbon installations located within residential buildings and outbuildings.
3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Whirlpool AKT 5000-NB at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Whirlpool AKT 5000-NB in the language / languages: English as an attachment in your email.

The manual is 1,82 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Whirlpool AKT 5000-NB

Whirlpool AKT 5000-NB User Manual - German - 7 pages

Whirlpool AKT 5000-NB User Manual - Dutch - 7 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info