813309
14
Zoom out
Zoom in
Previous page
1/30
Next page
14
WESTFIRE · WF 44 · WF 45 · WF 46
The Clean Air Act 1993 and Smoke Control Areas
Under the Clean Air Act local authorities may declare the whole or part of the district of the authority to be a
smoke control area. It is an offence to emit smoke from a chimney of a building, from a furnace or from any fixed
boiler if located in a designated smoke control area. It is also an offence to acquire an “unauthorised fuel” for
use within a smoke control area unless it is used in an exempt” appliance (“exempted” from the controls which
generally apply in the smoke control area).
In England appliances are exempted by publication on a list by the Secretary of State in accordance with changes
made to sections 20 and 21 of the Clean Air Act 1993 by section 15 of the Deregulation Act 2015. In Scotland
appliances are exempted by publication on a list by Scottish Ministers under section 50 of the Regulatory Reform
(Scotland) Act 2014. Similarly, In Northern Ireland appliances are exempted by publication on a list by the
Department of Agriculture, Environment and Rural Affairs under Section 16 of the Environmental Better regulation
Act (Northern Ireland) 2016. In Wales appliances are exempted by regulations made by Welsh Ministers.
Further information on the requirements of the Clean Air Act can be found here:
https://www.gov.uk/smoke-control-area-rules
Your local authority is responsible for implementing the Clean Air Act 1993 including designation and supervision
of smoke control areas and you can contact them for details of Clean Air Act requirements.
The WESTFIRE Uniq 44/ 45/ 46 SE stoves have been recommended as suitable for use in smoke control areas
when burning wood logs. The appliances have been fitted with a modification to fix the air controls at 56% open
for WESTFIRE Uniq 44/ 45/ 46 model in its minimum position.
Only specific SE models are suitable for smoke control areas, alterations should not be attempted.
Westfire smoke control stoves should not be burnt with the door left open.
The refuelling procedure : - allow the newly charged fuel to burn with the secondary air control set at maximum
for up 3 to 4 minutes. After this period, with flames from the logs fully established, close the secondary air supply
to the low output setting. When operating at high output (secondary air set fully open) the new refuel charge
does not require any boost air to establish combustion.
RE-FUELLING WHEN BURNING WOOD
BURNING WOOD IN A SMOKE CONTROL AREA
To re-fuel your stove in the cleanest way only refuel your stove when flames have died down and you have
glowing embers. Before refuelling, open air controls fully and slide. Unlatch door to equalise pressure with the
room. Open door gently, add one piece of wood and close the door. Once the flames from the logs are fully
established move air control to nominal position. The stove
is only suitable for intermittent use only: do not run overnight or for long periods unattended.
Experience will determine the settings that produce best results. Use a flue thermostat to check the stove is not
overheating. Flue thermostats should be placed directly above collar of the stove on a non insulated section of
pipe. (efficient operating temperature range is between 200c and 400c)
SE MODELS – smoke exemption modification
Smoke exempt models are factory fitted with a air stop on the air control slider:
Refuelling on to a low fire bed
If there is insufficient burning material in the firebed to light a new fuel charge, excessive smoke emission can
occur. Refuelling must be carried out onto a sufficient quantity of glowing embers and ash that the new fuel
charge will ignite in a reasonable period. If there are too few embers in the fire bed, add suitable kindling to
prevent excessive smoke.
UK
Stove Log length & weight
WF44 / WF45 / WF46 2 pieces approx 15 cm, 1.2 kg
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Westfire WF44 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Westfire WF44 in the language / languages: English, German, Dutch, Danish, French as an attachment in your email.

The manual is 1.14 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info