WESTFIRE · WF26 WF27 WF28
10
UNIQ 26,27,& 28
UK
Top flue exit 125 mm internal/150 mm external
Distance from rear to centre of flue
UNIQ 26: 156 mm
UNIQ 27 & 28: 192 mm
Rear flue exit 125 mm internal/150 mm external
Height to centre of rear flue
UNIQ 26, 27 & 28: 895 mm
Closed combustion air intake 100 mm
Height to centre of air intake
UNIQ 26, 27 & 28: 110 mm
Westfire Insulated chambers
The Westfire UNIQ 26, 27, 28 wood burning stove is lined with heat deflection panels and baffles, these panels
are designed to ensure the maximum efficiency and are an integral part of the clean burn process of the stove.
These baffles should not be removed apart from for cleaning the stove. Any defective panels should be replaced.
Connection to chimney
Westfire UNIQ 26, 27, 28 wood stove has both rear and top flue connector that allows connection to either a
masonry chimney or a prefabricated factory made insulated metal chimney in accordance with the instructions for
“Connection to chimney” given in the instruction booklet.
Commissioning and handover
Ensure loose parts are fitted in accordance with the instructions, page 13. ‘Vermiculite fire brick installation se-
quence’ before handover. Operation of primary and secondary air controls must be fully explained.
On completion of the installation allow a suitable period of time for any fire cement and mortar to dry out, when
a small fire may be lit and checked to ensure the smoke and fumes are taken from the stove up the chimney and
emitted safely to atmosphere. Do not run at full output for at least 24 hours.
On completion of the installation and commissioning ensure that the operating instructions for the stove are left
with the customer. Ensure to advise the customer on the correct use of the appliance with the fuels likely to be
used on the stove and warn them to use only the recommended fuels for the stove.
Advise the user what to do should smoke or fumes be emitted from the stove. The customer should be warned to
use a fireguard to BS 6539 in the presence of children, aged and/or infirm persons.
Operating your stove – UNIQ 26,27, 28
Initial lighting
The heat-resistant paint on your stove will cure and harden the first time you light your appliance. The curing process
produces a good deal of smoke and odour, it is therefore important that the first time you light your stove the room
should be well ventilated. During the process it is important to open and close the stove door periodically (every
30mins) during the first couple of firings therefore preventing the door seal cord around the door from sticking and
coming away from the door. Once the Heat-resistant paint has hardened; the stove door must be kept closed except
when lighting the stove, adding firewood or removing ash in order to prevent flue gas from escaping.
Lighting your appliance
Quality Firelighters should be used when lighting the stove. (Never use mentholated spirit, petrol or other
flammable liquids). Lighting your stove with fire lighters will be more reliable and easier than paper.
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Westfire WF28 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Westfire WF28 in the language / languages: English, German, Dutch, Danish, French as an attachment in your email.

The manual is 1.14 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info