784858
112
Zoom out
Zoom in
Previous page
1/124
Next page
PUMPE 2 A2
Spannung 230 V
Grün/Erde P51
Schwarz/Stufe1 K6-P
Rot/Stufe 2 K3-P
Weiss / Null P60
OZONATOR /
Zirkulationspumpe (B0)
(loser Anschluss)
Spannung 230 V
Grün/Erde P48
Schwarz/Leiter K2-P
Weiss / Null P57
ZIRKULATIONSPUMPE**
A1
Spannung 230 V
Grün/Erde P52
Schwarz/Leiter K4-P
Weiss / Null P62
LICHT 12 V AC, 1A MAX.
Spannung
Immer an P34
Relay P35
BLOWER /
ZIRKULATIONSPUMPE /
HBG* A4
Spannung 230 V
Grün/Erde P48
Schwarz/Stufe1 K6-P
Weiss / Null P57
PUMPE 1 A3
Spannung 230 V
Grün/Erde P49
Schwarz/Stufe1 K2-P
Rot/Stufe 2 K1-P
Weiss / Null P59
OZONATOR / Pumpe 3 /
Zirkulationspumpe (A1)
Spannung 230 V
Grün/Erde P52
Schwarz/Leiter K4-P
Weiss / Null P62
DIREKTER AUSGANGT 1
(loser Anschluss)
Spannung 230 V
Grün/Erde P47
Schwarz/Leiter P32
Weiss / Null P56
ANSCHLUSS VON HOCHSPANNUNGSGERÄTEN: W5000 (EUROPA-MODELLE)
Diese Hochspannungs-Verbindungen benötigen gerade, nicht isolierte männliche Schnellverbindungs-Stecker mit
sämtlichen Leitungen inkl. Erde. Bei ce-Pack (Europa-Modell) werden nur 230 V Geräte unterstützt. Folgen Sie
dem folgenden Plan, um die Geräte richtig anzuschliessen. Alle Stecker müssen korrekt auf die jeweiligen Steckplätze
gesteckt werden, um einen sicheren Stromfluss zu gewährleisten.
A3
A4
A1
A2
OPTIONAL
PP1 SPLITTER
A0
240V DIRECT
HEATING
ELEMENT
HEATER
GROUND
N
L2
L1
L3
P9
P82P81
K1
K3
K2
K4
K6
K9
K10
P33
P36
P37
P39
P40
P34
P19
P6
P2
P3
P4
P8
P29
P41 P45
P43
P44
P35
20A/400VAC MIN
CLASS aM
F2
20A/400VAC MIN
CLASS aM
20A/400VAC MIN
CLASS aM
F3
F1
F4
1
2
3
4
250mA/250VAC
3AG SLOW-BLO
P
P
P
P
P
CO C1CO
P11
P13
P14
P15
P28
P30
P32
P31
C
C
P22
P66
P55
P76
P74
P75
P17
P21
P7
P5
K8
P10
P
K5
TRANSFORMER
LIGHT, SWITCHED
P38
HL & TEMP.
PROBE
P42
IN.FLO
SENSOR
MAIN KEYPAD
COMMUNICATION LINKS
LIGHT, DIRECT
P83
G
N
P56
P57
P58
P59
P60
P61
P62
P47P48P49P50
P51
P52
P53
B0
- FOR PROPER GROUNDING, WIRES MUST BE CONNECTED
TO A TERMINAL ON THE PCB.
ALL OUTPUTS ARE CONFIGURED AS 240V BY PLUGGING THEIR
RESPECTIVE WIRES TO ANY TERMINAL ON THE PCB.
GREEN
G
WHITE N
230-240V ACCESSORIES:
WARNING
ANSCHLÜSSE
* HBG: Hilfs-Blasengenerator
** Ozonator und Zirkulationspumpe können einen gemeinsamen Ausgang verwenden. Hierfür ist der original splitter PP1
zu verwenden
Diese Tabelle zeigt typische Anschlüsse. OEMs können andere Anschluss-Schemen haben.
SCHALTPLAN  W3000 UND W5000
110
112


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Wellis W3000 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Wellis W3000 in the language / languages: German as an attachment in your email.

The manual is 12.46 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Wellis W3000

Wellis W3000 User Manual - English - 108 pages

Wellis W3000 User Manual - Dutch - 113 pages

Wellis W3000 User Manual - French - 108 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info