784857
103
Zoom out
Zoom in
Previous page
1/113
Next page
POMP 2 A2
Voltage 230 V
Groen/grond P51
Zwart / lage
snelheid K6-P
Rood / hoge-
snelheid K3-P
Wit / gemiddeld P60
OZONATOR / CP (B0)
(Zwevende verbinder)
Voltage 230 V
Groen/grond P48
Zwart/lijn K2-P
Wit / gemiddeld P57
CIRC. POMP** A1
Voltage 230 V
Groen/grond P52
Zwart/lijn K4-P
Wit / gemiddeld P62
LICHT 12 V AC, 1A MAX.
Voltage
Altijd aan P34
Relais P35
BLAZEN / CP /
ABG* (A4) 230 V
Voltage 230 V
Groen/grond P48
Zwart / lage
snelheid K6-P
Wit / gemiddeld P57
POMP 1 A3
Voltage 230 V
Groen/grond P49
Zwart / lage
snelheid K2-P
Rood / hoge-
snelheid K1-P
Wit / gemiddeld P59
OZONATOR / POMP 3 /
CP (A1) 230 V
Voltage 230 V
Groen/grond P52
Zwart/lijn K4-P
Wit / gemiddeld P62
DIRECTE UITGANG 1
(Zwevende verbinder)
Voltage 230 V
Groen/grond P47
Zwart/lijn P32
Wit / gemiddeld P56
VERBINDING HOOGSPANNING ACCESSOIRES: W5000 (EUROPEES)
Deze tabs vereisen een hoge-voltage accessoires om rechte, niet-geïsoleerde, vrouw snelverbindende terminals te hebben voor
alle verbindingen, met inbegrip van de grond. Bij -CE pakketten worden alleen 230V accessoires ondersteund. Zie de onderstaan-
de tabellen voor juiste verbindingen. Merk op dat alle volgende uitgangen juist en volledig moeten worden geplaatst op het
tabblad PCB voor de juiste huidige ratings.
A3
A4
A1
A2
OPTIONAL
PP1 SPLITTER
A0
240V DIRECT
HEATING
ELEMENT
HEATER
GROUND
N
L2
L1
L3
P9
P82P81
K1
K3
K2
K4
K6
K9
K10
P33
P36
P37
P39
P40
P34
P19
P6
P2
P3
P4
P8
P29
P41 P45
P43
P44
P35
20A/400VAC MIN
CLASS aM
F2
20A/400VAC MIN
CLASS aM
20A/400VAC MIN
CLASS aM
F3
F1
F4
1
2
3
4
250mA/250VAC
3AG SLOW-BLO
P
P
P
P
P
CO C1CO
P11
P13
P14
P15
P28
P30
P32
P31
C
C
P22
P66
P55
P76
P74
P75
P17
P21
P7
P5
K8
P10
P
K5
TRANSFORMER
LIGHT, SWITCHED
P38
HL & TEMP.
PROBE
P42
IN.FLO
SENSOR
MAIN KEYPAD
COMMUNICATION LINKS
LIGHT, DIRECT
P83
G
N
P56
P57
P58
P59
P60
P61
P62
P47P48P49P50
P51
P52
P53
B0
- FOR PROPER GROUNDING, WIRES MUST BE CONNECTED
TO A TERMINAL ON THE PCB.
ALL OUTPUTS ARE CONFIGURED AS 240V BY PLUGGING THEIR
RESPECTIVE WIRES TO ANY TERMINAL ON THE PCB.
GREEN
G
WHITE N
230-240V ACCESSORIES:
WARNING
AANSLUITINGEN
* ABG: Auxiliary Bubbel Generator
** Ozonator en circ pomp kunnen worden gecombineerd op dezelfde uitgang via de optionele snijmachine PP1.
Deze tabel toont de typische verbindingen. OEM's kunnen een andere verbinding regeling hebben.
BEDRADINGSSCHEMA  W3000 & W5000
102
103


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Wellis W2000 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Wellis W2000 in the language / languages: Dutch as an attachment in your email.

The manual is 4.73 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Wellis W2000

Wellis W2000 User Manual - English - 108 pages

Wellis W2000 User Manual - German - 124 pages

Wellis W2000 User Manual - French - 108 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info