Parts under electrical power – except those operating with
voltage not exceeding 12V - must be inaccessible for persons
in the spa. The grounded device must be connected to a
fixed socket with fixed wiring. Electrical parts – except
remote controllers – must be positioned so as not to fall into
the spa.
The electrical installation must meet the local standard
requirements.
To avoid electric shock do not use the spa in rain.
Water attracts children. Always place and lock the cover on
the spa after each usage.
Do not bury cables into the ground! Place the cables so that
lawnmowers, trimmers, and similar devices will not reach
them.
Do not force push the control panel up nor down and do not
place heavy objects on it after installation.
Keep pets away from the spa to avoid damage.
Do not use the device if there is the slightest chance of water
in the spa being frozen.
Only use accessories approved by us. The use of accessories
not approved by us may void the warranty.
Choking hazard. Particular attention need to be paid to
children during usage. To avoid accidents only allow children
to use this spa under adult supervision.
Never operate electrical devices in the spa or with wet body.
Do not place electrical devices (lamp, radio, television) within
a 1.5m radius of the spa.
Do not expose the spa to direct sunlight.
Only connect the spa to an earthed socket.
Risk of electric shock. Install the unit at least 1.5m (5 feet)
from any metal surfaces. You can install the unit 1.5m from
metal surfaces only if every metal surface is permanently
connected to a solid copper conductor
with a diameter of at least 6mm, which is connected to the
cable connector of a junction box reserved for that purpose.
To avoid injury never pour water warmer than 40°C directly
into the spa.
Effects of overheating: you cannot assess emergency situa-
tions, do not feel the temperature, do not feel the need to get
out of the spa, cannot get out of the spa; risk of fetal damage
in pregnant women, loss of consciousness, suffocation.
Do not use the spa alone.
Do not use the spa immediately after strenuous sport.
To prevent damage to the pump the spa can only be operat-
ed if it has been filled with water.
If you feel uncomfortably or sleepy, leave the spa immedi-
ately.
Never add water to the chemicals. Always be cautious when
adding chemicals to the spa water to avoid inhaling vapors
and possible effects of inhaling undiluted chemicals and
splatters.
Only place the spa on a surface that can support its weight.
INSPECT THE UNIT BEFORE USE. CONTACT THE SER-
VICE PROVIDER STATED IN THIS MANUAL IF ANY
OF THE PARTS WERE DAMAGED OR MISSING UPON
PURCHASE. ENSURE THAT THE PARTS OF THE UNIT
ARE THOSE WHICH YOU INTENDED TO BUY.
IN.CLEAR SAFETY WARNINGS
Beyond the previous warnings, please also pay attention to
the undermentioned ones
Read this manual carefully, always follow its instructions, and
retain it. This manual contains important information about
the installation, operation, and safety recommendations of
the in.clear unit. Safe installation and usage is your respon-
sibility.
The in.clear unit must be connected to a network protected
by a ground fault circuit interrupter (GFCI) of the maximal
nominal fault current value of 30mA.
Ensure that the entire power supply is turned off before the
in.clear unit is installed.
If the power cord is damaged, it must be replaced by the
manufacturer, an authorized service provider, or qualified
professionals to avoid emergencies.
Always use a proper electric cable for supply of current to the
in.clear unit.
When installing the in.clear Automatic Bromine Generator
local and international electrical regulations must be com-
plied with.
Clean or replace the filter cartridge at regular intervals, oth-
erwise part of the bromine produced by the in.clear unit will
be consumed by oxidation of contamination accumulated in
the filter.
DO NOT pour any other chemicals into the spa than the
recommended sodium bromide. DO NOT use any ozone or
UV disinfectant.
Operating the in.clear unit on lower sodium bromide level
shortens the life of the cells. Keeping sodium bromide and
bromine levels above the recommended level may lead to
corrosion of the spa components and cause damage to the
spa accessories.
Do not open the in.clear unit; it does not contain serviceable
parts
Product disposal: the in.clear unit must be disposed of in
accordance with local disposal regulations in force.
This device is not intended for use by persons (nor children)
with limited physical, sensory, or mental capabilities except if
these persons have received appropriate instruction on use
of the device from the person responsible for their safety.
The in.clear unit cannot be applied to in-ground sunken spas
as it may affect materials used in the construction.
The shut-off device must have fixed wiring in accordance
with the cabling regulations.
Showering is compulsory before each spa use.
The user is responsible for regular monitoring of the spa
water to ensure that enough bromine is available to reach
the appropriate cleaning level. Intensive spa use may require
higher bromine intake to always maintain appropriate
bromine level.
Always check the expiry date of the test kit, because after this
date the test results may be inaccurate.
For proper disinfection spas must periodically be completely
drained. The advised time period between full drains given in
days is calculated by dividing the capacity of the spa in litres
by the tenfold of the average daily users.
The in.clear unit is applicable for indoor spas, but NOT for
swimming pools.
SAFETY INSTRUCTIONS
4
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Wellis In.Touch2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Wellis In.Touch2 in the language / languages: English as an attachment in your email.

The manual is 11.71 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Wellis In.Touch2

Wellis In.Touch2 User Manual - German - 124 pages

Wellis In.Touch2 User Manual - Dutch - 113 pages

Wellis In.Touch2 User Manual - French - 108 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info