W8000 230 V OR 230/400 V
Correct wiring of the electrical service box, RCD,
and pack terminal block is essential!
Call an electrician if necessary.
ELECTRICAL WIRING: W8000 (EUROPEAN)
Refer to wiring diagram in the enclosure box lid for more information.
2-phase used from 3-phase
Delta – no neutral
Use 2-phase setting
L1+L2 currents return
through L3
Connect PJ1 between P7 and
P10. Connect PJ2 between
P13 and P74.
1-phase
L1 current returns through
neutral
Connect PJ1 between P7 and
P13. Connect PJ2 between
P10 and P74.
2-phase
with single neutral L1+L2
currents return through
neutral
Connect PJ1 between P7 and
P10. Connect PJ2 between
P13 and P74.
3-phase with single neutral
L1, L2+L3 currents return
through neutral
Connect PJ1 between
P7 and P10. Connect PJ2
between P11 and P13.
WARNING!
W8000 models must always be connected to a circuit
protected by a Residual-Current Device (RCD) having
a rated operating residual-current not exceeding 30
mA.
PJ2
PJ1
N
L1
G
NPJ2
PJ1
L1
L2
G
L3 PJ2
PJ1
L1
L2
G
ELECTRICAL WIRING
WIRING DIAGRAM  W8000
NPJ2
PJ1
L1
L2
L3
G
101
103


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Wellis In.Grid at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Wellis In.Grid in the language / languages: English as an attachment in your email.

The manual is 11.71 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Wellis In.Grid

Wellis In.Grid User Manual - German - 124 pages

Wellis In.Grid User Manual - Dutch - 113 pages

Wellis In.Grid User Manual - French - 108 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info