SITE PREPARATION
When choosing a site for the spa take into account that its
maintenance and repair works must be carried out behind
the sidewalls, so accessibility and space to walk around the
spa must be ensured.
1. INDOOR/BASEMENT INSTALLATION
If you place your spa indoors, be aware of some special
requirements:
Water may accumulate around the spa, so the flooring mate-
rial must have a proper runoff to avoid accumulation of water.
When building a new room for the spa, constructing a floor
drain is required, or damages may occur due to overflow,
overfilling, or technical failure. Our company does not take
responsibility for any damage in absence of floor drainage.
Humidity will naturally increase in the room where the spa is
located and the evaporated water condenses. For this reason
ensure that the area has proper ventilation. We recommend
installing a dehumidifier in the room.
2. OUTROOR AND PATIO INSTALLATION
A solid horizontal foundation is necessary for installation of
the spa. We advise using a reinforced concrete foundation at
least 10-15cm thick.
Ensure that your deck or foundation will support your spa.
You must know the maximal load capacity of the foundation.
Consult a qualified building contractor or structural engineer.
To find out the weight of your spa, its contents and occupants
please refer to the spa specification chart. This weight must
not exceed the structure’s rated capacity per square meter,
otherwise serious structural damages could result. If you
install the spa outdoors, we recommend a reinforced hori-
zontal concrete pad at least 10-15cm thick.
Install floor drains around your spa to lead water away even
in heavy rain.
When constructing the water drain it is advised to form a 10-
15cm deep sloping ditch around the spa which directs water
to the drain. Water from the drain must be directed to the
canal or a drainage with enough capacity.
Warning: Do not expose the spa to direct sunlight (not even
empty) without proper coverage. The insulated spa cover
preserves the water temperature and provides protection from
sunlight and rain. When exposed to sunshine for a longer period
it may damage the surface of the spa and the spa equipment.
Acrylic rapidly absorbs heat from sun rays, thus reaches a
very high surface temperature which may damage the spa.
In case of sealed design, if the spa was placed between glass
structures, prevent the sun rays from reaching the spa direct-
ly through the glass as the temperature may get too high.
3. IN-GROUND / SUNKEN SPA
In case of sinking the spa into the ground you must make
sufficient space for walking around the spa. For completion
of maintenance works a minimum of 60cm wide inspection
pit must be built around the spa.
The inspection pits bottom must be under the bearing pont
of the spa so that water can flow into the pit in case of water
leakage. A floor drain or sump pump should be used at the
bottom of the pit to ensure continual water drainage.
In case of sinking the spa only the portion below the spa’s
acrylic edge can be sunk. The air of the inspection pit steams
up. To prevent unpleasant odors proper ventilation must be
provided (e.g. installing ventilators). The costs of pulling the
spa out of the ground are borne by the user. If the aforemen-
tioned conditions are not present, setting up the spa may fail.
First filling of the spa
Proper filling of the spa is an important task both technically
and chemically. We advise installation and periodic mainte-
nance by the servicing professionals, which includes inspec-
tion and refilling of spa water. Spas do not contain water
softener and hard water damages the equipment. Improper
filling of the spa may bring air into the system, which damag-
es the heating wire and engines. Pure stream WE00067 (water
softener) and Pure fill WE00068 (carbon filter) are ensured for
your spa. Please fill your spa exclusively through this filters.
Repairs after such failures are not covered by warranty.
Filling process
Remove the spa cover. First remove the cover staves, then
remove the side covers by unscrewing the bottom screws.
During transportation the flare fittings of engines may
dislocate. Check these connections before installation. If
necessary, tighten the flare fittings.
In spas equipped with air engine the flare fitting must be
connected before running the spa for the first time.
Before filling the spa check that the ratchets are not in a
closed state (lever is pulled out and fixed with the safety
lock).
Next fill the spa with water to the sign indicated on its
sidewall.
Filling must be done through the filter housing. Improper
filling can damage the engines and heating element.
Insert the filter or filter cartridges when proper water level
is reached. Be cautious, because when replacing the filter
cartridge air bubbles may remain in the cartridge. To avoid
this the filter cartridges must be tilted in the water to remove
air from them, and only then fitted to their place.
INITIAL INSTALLATION
6
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Wellis Easy 7 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Wellis Easy 7 in the language / languages: English as an attachment in your email.

The manual is 11.71 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Wellis Easy 7

Wellis Easy 7 User Manual - German - 124 pages

Wellis Easy 7 User Manual - Dutch - 113 pages

Wellis Easy 7 User Manual - French - 108 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info