UVC WATER TREATMENT
WARNING: THE GERMICIDAL ULTRAVIOLET RAYS
ARE HARMFUL TO THE EYES, SKIN.
INTEGRATION:
1. Install the sterilization equipment at an easy to reach well
lit place for effortless observation and maintenance.
2. Lock the clamp on the frame.
3. Insert the chamber with the help of the clamps.
4. Connect to the water supply.
5. Insert the quartz sleeve, sealing ring, lamp.
IMPORTANT: DO NOT TOUCH THE QUARTZ SLEEVE
OR THE SIDES OF THE LAMP, ONLY HOLD IT BY THE
TWO ENDS.
The ultraviolet lamp and the quartz can easily be damaged.
Take care when removing or changing the lamp or the quartz
sleeve.
a. Take off the nut. (2).
b. Carefully slide the quartz sleeve (6) from one end of the
chamber to the other.
c. Slide the sealing ring (5) onto the free end points of the
quartz sleeve.
d. Squeeze the aluminum nut on by hand (2).
e. Slide the lamp (4) into the quartz sleeve.
f. Connect the lamp to the casing.
g. Screw the nut to the chamber, then screw on the water
resistant lid (1) to the nut (2).
h. Open the tap and check if the device is leaking. Repair as
necessary.
I. Plug the device into the electric supply. Use a socket
equipped with a fault circuit interrupter (GFCI).
Malfunction of the UVC water sanitizer is indicated by the LED
logo flashing in red. In this case, replacement of the fluores-
cent tube is necessary.
CHANGING THE LAMP AND SERVICING THE UV
SYSTEM
Important: Do not touch the quartz sleeve or the sides of the
lamp, only hold it by the ends.
1. Unplug the power plug.
2. Shut down and drain the water from the device to lessen
pressure.
3. Take off the PVC lid (1) and unscrew the aluminum nut (2).
4. Carefully pull out the lamp (4) to approximately 5cm from
the chamber (7).
5. Holding the lamp by the end carefully remove the lamp
casing (3) on the free end.
6. Carefully take the lamp out of the chamber.
7. Carefully take off the sealing ring (5) from the end of the
quartz sleeve.
8. Carefully take off the quartz sleeve.
9. To reinstall follow instructions 1 to 8 in reversed order
MAINTENANCE SUGGESTION:
In order for the sterilizer to work properly and with maximal
efficiency the user should perform the following mainte-
nance tasks.
1. Cleaning, changing the quartz sleeve:
a) The quartz sleeve is to be cleaned with a glass cleaner
solution every 6-12 months.
b) The quartz sleeve is to be changed every 24 months.
2. Changing the UV lamp is recommended after 8-9000 op-
erating hours (about 12 months of continuous operation).
3. To acquire interchangeable parts contact our headquar-
ters or the local representatives of our company.
1- Water resistant lid
2- Aluminum nut
3- Lamp casing, wire outlet
4- Germicidal ultraviolet lamp
5- Rubber sealing ring
6- Quartz sleeve
7- Chamber
8- Pawl
9- Transformer
OPTIONAL ACCESSORIES  UVC
55
57


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Wellis Aquasoul Pro at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Wellis Aquasoul Pro in the language / languages: English as an attachment in your email.

The manual is 11.71 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Wellis Aquasoul Pro

Wellis Aquasoul Pro User Manual - German - 124 pages

Wellis Aquasoul Pro User Manual - Dutch - 113 pages

Wellis Aquasoul Pro User Manual - French - 108 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info