784851
5
Zoom out
Zoom in
Previous page
1/108
Next page
FOR YOUR SAFETY PLEASE ALWAYS PERFORM THE
FOLLOWING PRECAUTIONS. IF YOU DO NOT FOL-
LOW THE WARNINGS AND INSTRUCTIONS, ITEMS
MAY GET DAMAGED, YOU MAY GET INJURED,
OR YOU MAY SUFFER FATAL INJURY. IMPROPER
INSTALLATION AND OPERATION INVALIDATES THE
WARRANTY.
Initial safety warnings
The spa must be powered through a residual current device
(RCD) with a current release not exceeding 30mA.
The devices and parts which contain active parts – except
those which are powered from protective extralow voltage
not exceeding 12V – must be inaccessible from the spa.
ABOUT THE ENVIROMENTALLY SAFE WATER
DRAINING
The spa must be powered through a residual current device
(RCD) with a current release not exceeding 30mA.
The devices and parts which contain active parts – except
those which are powered from protective extralow voltage
not exceeding 12V – must be inaccessible from the spa.
About the enviromentally safe water draining
The water temperature in the spa should never exceed
40°C (104°F). The water temperature is considered safe for
a healthy adult at 36 to 38°C. Lower water temperature is
recommended for younger children or when the spa is used
for more than 10 minutes.
Spa heat can cause hyperthermia!
Symptoms: drowsiness, heaviness
Children under 14 years of age can only use and operate the
products mounted with hydromassage system under adult
supervision.
People with heart disease, low or high blood pressure,
circulatory disorders, diabetes, and excessive weight should
consult their physician prior to using the spa.
Consumption of alcohol or drugs while using the spa greatly
increases the chance of fatal overheating.
A person taking medications should consult a doctor before
using the spa as some medicines may cause drowsiness
while others may affect the heart rate, blood pressure, and
circulation.
Persons who suffer from infectious diseases should not use
the spa.
Because high water temperature poses a high risk to the
fetus and may cause serious fetal damage we advise that
(potentially) pregnant women do not use the spa at a water
temperature higher than 38°C. Wet surfaces can be slippery.
Note and warn your child about this when entering and
leaving the spa. To avoid injury carefully get into and out of
the spa.
Do not use the spa if the suction cover is damaged or missing.
Never place any electric device within a 2-meter radius of the
spa - it can cause electrical shock. Electric devices fallen into
water may cause death, electric shock, or serious personal
injuries.
It is prohibited to remove the panels while using the spa.
Water treatment should be carried out with caution. Improp-
erly chemically treated* water may cause skin irritation.
When the spa is not in use, cover the spa with the cover to
prevent ultraviolet radiation causing damage to the product.
Do not allow your child to climb on the thermo cover when it
is on the water-filled spa.
Do not remove any suction sealing. Do not operate the spa if
the suction sealing is broken or missing.
WARNING! The metallic parts of the pool may become hot
when exposed to sunlight and can cause injury!
Keep your clothes and jewellery away from rotating jets and
moving parts.
Test the residual current device before use.
Disconnect the spa from the power supply before servicing
its electrical parts. (This operation can only be performed by
qualified professionals).
It is strictly prohibited to use the spa in a not completely
assembled state (e.g. detached side panel)
Chemical treatment of water can only be performed by per-
sons under the age of 18 under parental supervision.
Maintenance can only be performed by trained professionals.
The user should check the electrical wiring every 3 months. It
is required to perform a check by a professional every 3 years.
Mains fuses / circuit breakers may be activated because of
power outages.
Installation and wiring of the spa, replacement of power cord,
and any repairs must be performed by qualified professionals.
It is required to build in an isolating device to the fixed wiring.
Plug’n’play safety warnings
Beyond the previous warnings, please also pay
attention to the undermentioned ones.
ATTENTION! The electrical receptacle must be located at least
2.5 meters from the spa so that bathers in a sitting position
cannot reach it from the water. The plug can only be connected
to a receptacle* equipped with 2.5mm 2 diameter cables
ATTENTION! RISK OF ELECTRIC SHOCK. The connector with
residual current device must be inspected before every use.
ATTENTION! Only place the RCD plug in a receptacle equipped
with RCD.
ATTENTION! Before you insert the plug into the socket ensure
that the current of the socket and the fixed wiring is appropriate
for the properties of the spa.
The spa must be equipped with an isolation transformer or
powered through a residual current device with a release
current not exceeding 30mA.
THIS PRODUCT IS EQUIPPED WITH A GROUND
FAULT CIRCUIT BREAKER (GFCI) IN THE CONNEC-
TOR. GFCI MUST BE TESTED BEFORE EACH USE.
If the power cable is damaged, it must immediately be re-
placed by the manufacturer or a service professional in order
to minimize danger.
To minimize the risk of electric shock do not use extension
leads to connect the product to the power supply.
Ensure that the receptacle is properly located.
Parts of the equipment cannot be placed above the spa
during usage.
SAFETY INSTRUCTIONS
3
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Wellis Aquasoul Pro at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Wellis Aquasoul Pro in the language / languages: English as an attachment in your email.

The manual is 11.71 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Wellis Aquasoul Pro

Wellis Aquasoul Pro User Manual - German - 124 pages

Wellis Aquasoul Pro User Manual - Dutch - 113 pages

Wellis Aquasoul Pro User Manual - French - 108 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info