8
8
Select the “FCC” High or Low Set point with the
U
U
P
P
or
D
D
O
O
W
W
N
N
Scroll Key. After the “FCC” function is complete
at both “Set” points, Radio Button
2
2
is used to exit the
menu.
U
U
P
P
Scroll Key: High “Set” point 842°F/450°C
D
D
O
O
W
W
N
N
Scroll Key: Low “Set” point 212°F/100°C
R
R
e
e
s
s
e
e
t
t
t
t
i
i
n
n
g
g
t
t
h
h
e
e
S
S
p
p
e
e
c
c
i
i
a
a
l
l
F
F
u
u
n
n
c
c
t
t
i
i
o
o
n
n
s
s
t
t
o
o
F
F
a
a
c
c
t
t
o
o
r
r
y
y
S
S
e
e
t
t
t
t
i
i
n
n
g
g
s
s
Press and hold the
2
2
Radio Button. Then press the
U
U
P
P
and
D
D
O
O
W
W
N
N
Scroll Keys at the same time. "
F
F
S
S
E
E
",
“Factory Setting Enabled” appears in the display. The
station is now reset to its factory default settings.
I
I
m
m
p
p
o
o
r
r
t
t
a
a
n
n
t
t
:
:
T
T
h
h
e
e
s
s
o
o
l
l
d
d
e
e
r
r
i
i
n
n
g
g
t
t
o
o
o
o
l
l
b
b
e
e
c
c
o
o
m
m
e
e
s
s
h
h
o
o
t
t
d
d
u
u
r
r
i
i
n
n
g
g
t
t
h
h
e
e
F
F
a
a
c
c
t
t
o
o
r
r
y
y
C
C
o
o
n
n
t
t
r
r
o
o
l
l
C
C
h
h
e
e
c
c
k
k
.
.
N
N
e
e
v
v
e
e
r
r
l
l
e
e
a
a
v
v
e
e
c
c
o
o
m
m
b
b
u
u
s
s
t
t
i
i
b
b
l
l
e
e
m
m
a
a
t
t
e
e
r
r
i
i
a
a
l
l
s
s
n
n
e
e
a
a
r
r
t
t
h
h
e
e
h
h
o
o
t
t
s
s
o
o
l
l
d
d
e
e
r
r
i
i
n
n
g
g
i
i
r
r
o
o
n
n
.
.
7
7
.
.
2
2
.
.
2
2
A
A
d
d
j
j
u
u
s
s
t
t
i
i
n
n
g
g
F
F
a
a
c
c
t
t
o
o
r
r
y
y
C
C
o
o
n
n
t
t
r
r
o
o
l
l
C
C
h
h
e
e
c
c
k
k
S
S
e
e
t
t
t
t
i
i
n
n
g
g
s
s
(
(
F
F
C
C
C
C
)
)
C
C
o
o
n
n
t
t
r
r
o
o
l
l
C
C
h
h
e
e
c
c
k
k
a
a
t
t
2
2
1
1
2
2
°
°
F
F
/
/
1
1
0
0
0
0
°
°
C
C
D
D
e
e
p
p
r
r
e
e
s
s
s
s
t
t
h
h
e
e
D
D
O
O
W
W
N
N
S
S
c
c
r
r
o
o
l
l
l
l
K
K
e
e
y
y
The station sets the temperature of the soldering tip to
212°F/100°C. Once the temperature becomes stable (at
which point the indicator flashes), the soldering tip
temperature reading on the external device is compared
to that shown on the station display. If the temperature
readings differ, the
U
U
P
P
/
/
D
D
O
O
W
W
N
N
Scroll Keys can be used
to make adjustments. The temperature Offset is indicat-
ed in the display. A maximum temperature adjustment
of ±72°F/±40°C is possible. After the measured temper-
ature matches that shown on the station display,
depress the Radio Button
I
I
-
-
I
I
I
I
-
-
I
I
I
I
I
I
to confirm. The temper-
ature Offset is reset to “0”. This concludes the Factory
Control Check adjustments at 212°F/100°C.
Press Radio Button 2 to exit the menu without saving
any changes.
C
C
o
o
n
n
t
t
r
r
o
o
l
l
C
C
h
h
e
e
c
c
k
k
a
a
t
t
8
8
4
4
2
2
°
°
F
F
/
/
4
4
5
5
0
0
°
°
C
C
D
D
e
e
p
p
r
r
e
e
s
s
s
s
t
t
h
h
e
e
U
U
P
P
S
S
c
c
r
r
o
o
l
l
l
l
K
K
e
e
y
y
The station sets the temperature of the soldering tip to
842°F/450°C. Once the temperature becomes stable (at
which point the indicator flashes), the soldering tip
temperature reading on the external device is compared
to that shown on the station display. If the temperature
readings differ, the
U
U
P
P
/
/
D
D
O
O
W
W
N
N
Scroll Keys can be used
to make adjustments. The temperature offset is indicat-
ed in the display. A maximum temperature adjustment
of ±72°F/±40°C is possible. After the measured temper-
ature matches that shown on the display, depress the
Radio Button
I
I
-
-
I
I
I
I
-
-
I
I
I
I
I
I
to confirm. The temperature offset
is reset to 0. This concludes the Factory Control Check
adjustment at 842°F/450°C.
Press Radio Button
2
2
to exit the menu without saving
any changes.
After both control points, 212°F(100°C) and 842°F
(450°C), have been set and confirmed, the Factory
Control Check process is complete.
7
7
.
.
2
2
.
.
3
3
S
S
t
t
a
a
t
t
i
i
o
o
n
n
C
C
o
o
d
d
e
e
(
(
I
I
D
D
n
n
u
u
m
m
b
b
e
e
r
r
)
)
When using multiple WD stations, you can assign a
number from 0 - 999 to each soldering station for iden-
tification purposes.
Use the
U
U
P
P
/
/
D
D
O
O
W
W
N
N
Scroll Keys to change the ID num-
ber.
Switch to previous menu item with Radio Button
1
1
.
Switch to next menu item with Radio Button
I
I
-
-
I
I
I
I
-
-
I
I
I
I
I
I
.
Radio Button
2
2
is used to exit Special Functions Menu
842°F /450°C
212°F /100°C
Temperature
Deviation
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Weller WD2M at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Weller WD2M in the language / languages: English as an attachment in your email.

The manual is 0,44 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Weller WD2M

Weller WD2M User Manual - All languages - 171 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info