Montage- und Betriebsanleitung
WWP S 6 IDT-2 - WWP S 11 IDT-2
4 Stromlaufpläne Wärmepumpenmodul
452236.66.07 · 01/2016 · Rei XVII
4.4 Legende
F4 Hochdruckpressostat High-pressure switch Pressostat haute pression
F5 Niederdruckpressostat Low-pressure switch Pressostat basse pression
F7 Heißgasthermostat Hot gas thermostat Thermostat gaz de chauffage
F12 Störmeldekontakt N7 Fault alarm contact N7 Servomoteur pour détendeur N7
K1 Schütz M1 Contactor M1 Contacteur M1
M1 Verdichter Compressor Compresseur
M7 Stellmotor für Expansionsventil Actuator for expansion valve
N1* Wärmepumpenmanager Heat pump controller Gestionnaire de pompe à chaleur
N7 Sanftanlaufsteuerung M1 Soft start control M1 Commande de démarrage progressif M1
N23* Ansteuerung elektronisches Expansionsventil
E*V connection (1=grün, 2=gelb, 3=braun, 4=weiß)
Activation of the electronic expansion valve
E*V connection (1=green, 2=yellow, 3=brown,
4=white)
Commande détendeur électronique Connexion dét.
(1=vert, 2=jaune, 3=marron, 4=blanc)
R25 Drucksensor Kältekreis - Niederdruck po Pressure sensor for refrigeration circuit -
low pressure pO
Capteur de pression circuit frigorifique -
basse pression po
R26 Drucksensor Kältekreis - Hochdruck pc Pressure sensor for refrigeration circuit -
high pressure pc
Capteur de pression circuit frigorifique -
haute pression pc
R27 Sauggasfühler Suction gas sensor Sonde de gaz d'aspiration
T1 Sicherheitstransformator 230 / 24 V AC Safety transformer 230 / 24 V AC Transformateur de sécurité 230 / 24 V AC
W1* Verbindungsleitung Wärmepumpe -
Manager 230 V
Connection cable heat pump manager 230 V Ligne de raccordement de la pompe à chaleur -
Gestionnaire 230 V
W2* Verbindungsleitung Wärmepumpe -
Manager <25 V
Connection cable heat pump manager <25 V Ligne de raccordement de la pompe à chaleur -
Gestionnaire <25 V
W3* Busleitung N1 <--> N23 Bus cable N1 <--> N23 Ligne de bus N1 <--> N23
W4* Lastleitung Mains cable Ligne de puissance
X1.1 Stecker Einspeisung Lastspannung Plug supply voltage infeed Connecteur alimentation tension de puissance
X2 Klemmleiste Spannung = 230 V AC Terminal strip voltage = 230 V AC Tension bornier = 230 V AC
X3 Klemmleiste Kleinspannung < 25 V AC Terminal strip extra-low voltage < 25 V AC Faible tension bornier < 25 V AC
X12 Stecker 230 V Steuerspannung Plug 230 V control voltage Connecteur tension de commande 230 V
X13 Stecker Steuerkleinspannung Plug small control voltage Connecteur faible tension de commande
* Bauteile sind bauseits anzuschließen / beizustellen Components must be connected / supplied by the
customer.
Les pièces sont à raccorder / à fournir par le client
____ werkseitig verdrahtet Wired ready for use câblé en usine
------ bauseits nach Bedarf anzuschliessen to be connected on site if required à raccorder par le client si besoin
47


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Weishaupt WWP S 11 IDT-2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Weishaupt WWP S 11 IDT-2 in the language / languages: German as an attachment in your email.

The manual is 2.55 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Weishaupt WWP S 11 IDT-2

Weishaupt WWP S 11 IDT-2 User Manual - Dutch - 52 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info