813755
100
Zoom out
Zoom in
Previous page
1/116
Next page
Montage- und Betriebsanleitung
Hydraulikeinheit WWP LS 8 … 16-B
11 Technische Unterlagen
83306901 1/2018-05 Ber 100-116
Warmwasser Werkeinstellung Einstellbereich
Warmwasser-Push Aus Aus / 5…240min
Warmwasser-Solltempera-
tur
Normal 45,0°C 20°C…Warmwasser-
Maximaltemperatur
Absenk 35°C 10°C…Normal
Legionellenschutz Tag Aus
Aufheizzeit WW 2h 0:00…23:50Uhr
Aufheiztemperatur
WW
60°C 20°C…Warmwasser-
Maximaltemperatur
Ladungsdauer 120min Aus / 5…240min
Einstellungen SG REady Anhebung Aus Aus / 0…30K
Maximaltemperatur 60°C 20…80°C
Vorlaufüberhöhung 7K 0…50K
Flanschheizung Umschalttemperatur 52°C 20…65°C
Schaltdifferenz 2K 1…20K
Reset Aus [Kap.]
Wärmepumpe Werkeinstellung Einstellbereich
Service Automatische Ent-
lüftung
Aus [Kap.6.7.5.1]
Handbetrieb Aus [Kap.6.7.5.1]
manuelle Abtauung Aus [Kap.6.7.5.1]
Test Aus [Kap.6.7.5.1]
Einstellungen Standzeit 10,0min 3…360min
Außenfühlerzuord-
nung
Luftansaugtemperatur [Kap.6.7.5.2]
Ruhemodus Aus [Kap.6.7.5.2]
Leistungsbegrenzung
AT
5,0°C -20…40°C
Spreizungsüberwa-
chung
Ein [Kap.6.7.5.2]
Schaltdifferenz dy-
namisch
Ein [Kap.6.7.5.2]
Modulation Leistung Warmwasser Automatik [Kap.6.7.5.4]
Pumpe Einschaltart Konstantbetrieb [Kap.6.7.5.5]
Leistung Heizen 80% 1…100%
Leistung Kühlen 80% 0…100%
Leistung Warmwasser 80% 0…100%
Freigabe bei EVU-
Sperre
Aus [Kap.6.7.5.5]
Heizen Schaltdifferenz 3,0K 1…30K
Leistungsbegrenzung 100% 10…100%
Kühlen Schaltdifferenz -3,0K -30…1K
Leistungsbegrenzung 100% 50…100%
Warmwasser Minimaltemperatur 45,0°C 45…65°C
Schaltdifferenz 5,0K 1…30K
Reset Aus [Kap.6.7.3.11]
100


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Weishaupt WWP LS 13-B R at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Weishaupt WWP LS 13-B R in the language / languages: German as an attachment in your email.

The manual is 3.28 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Weishaupt WWP LS 13-B R

Weishaupt WWP LS 13-B R User Manual - German - 60 pages

Weishaupt WWP LS 13-B R User Manual - Dutch - 108 pages

Weishaupt WWP LS 13-B R User Manual - Dutch - 60 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info