Montage- en bedieningsrichtlijnen
Gascondensatieketel WTC-GB 15 … 32-B
11 Technische documenten
83326607 1/2022-08 Luw 150-208
Hydraulische variante Componenten / instellingen Verklaring
P1
WTC uitvoering H
Componenten:
Buffervat
Instellingen:
Directe warmwaterkring: neen
Directe stookkring: neen
Fabrieksinstelling:
P 2.2.1: Proportioneel vgl.
vermogen
De interne pomp van de WTC laadt het
buffervat.
Uitbreidingsmodules regelen de
stookkringen na het buffervat.
Aansluiting WTC:
B1: buitenvoeler
Aansluiting WEM-EM-Sol:
B10: Buffervatvoeler bovenaan
B11: Buffervatvoeler onderaan
(optioneel)
P2
WTC uitvoering H
Componenten:
Multifunctionele boiler
Instellingen:
Directe warmwaterkring: ja
Directe stookkring: neen
Fabrieksinstelling:
P 2.2.1: Proportioneel vgl.
vermogen
P 2.2.2: Debietregeling
P 6.1.5: Parallel
De interne pomp van de WTC laadt de
multifunctionele boiler.
De WTC regelt de warmwaterlading.
Uitbreidingsmodules regelen de
stookkringen na de multifunctionele boiler.
Aansluiting WTC:
MFA1: circulatiepomp WW1 (indien
voorhanden)
B1: buitenvoeler
B3: warmwatervoeler
T1: circulatievoeler (indien voorhanden)
Aansluiting WEM-EM-Sol:
B10: Buffervatvoeler bovenaan
B11: Buffervatvoeler onderaan
(optioneel)
P3
WTC uitvoering H
Componenten:
Multifunctionele boiler
Extern drie-weg-ventiel
Instellingen:
Directe warmwaterkring: ja
Directe stookkring: neen
Fabrieksinstelling:
P 2.2.1: Proportioneel vgl.
vermogen
P 2.2.2: Debietregeling
P 6.1.5: Parallel
De interne pomp van de WTC laadt de
multifunctionele boiler via het drie-weg-
ventiel.
De WTC regelt de warmwaterlading.
Uitbreidingsmodules regelen de
stookkringen na de multifunctionele boiler.
Aansluiting WTC:
MFA1: drie-weg-ventiel
VA2: circulatiepomp WW1 (indien
voorhanden)
B1: buitenvoeler
B3: warmwatervoeler
T1: circulatievoeler (indien voorhanden)
Aansluiting WEM-EM-Sol:
B10: Buffervatvoeler bovenaan
B11: Buffervatvoeler onderaan
(optioneel)
P4
WTC uitvoering H
Componenten:
Buffervat
Platenwarmtewisselaar
Externe buffervatlaadpomp
Instellingen:
Directe warmwaterkring: neen
Directe stookkring: neen
Fabrieksinstelling:
P 2.2.1: Proportioneel vgl.
vermogen
De interne pomp van de WTC voedt de
platenwarmtewisselaar.
De externe pomp laadt enkel het buffervat.
Uitbreidingsmodules regelen de
stookkringen na het buffervat.
Aansluiting WTC:
MFA1: Buffervatlaadpomp
B1: buitenvoeler
B2: voeler platenwarmtewisselaar
Aansluiting WEM-EM-Sol:
B10: Buffervatvoeler bovenaan
B11: Buffervatvoeler onderaan
(optioneel)
150


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Weishaupt WTC-GB 25 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Weishaupt WTC-GB 25 in the language / languages: Dutch as an attachment in your email.

The manual is 6.85 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Weishaupt WTC-GB 25

Weishaupt WTC-GB 25 User Manual - German - 216 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info