813634
15
Zoom out
Zoom in
Previous page
1/24
Next page
Installatievoorschriften voor de installateur
WPM 5.0M
2 Stroomschema's
452115.66.30 · 04/2015 · Rei V
Legenda
Brug energiebedrijfsblokkering: moet worden geplaatst indien er geen EVB-veiligheidsschakelaar voorhanden is
(contact open = energiebedrijfsblokkering).
Brug blokkering: moet worden verwijderd, wanneer de ingang wordt gebruikt
(ingang open = WP geblokkeerd).
K23 Hulprelais voor blokkeringsingang
B3 Thermostaat warm water / SG Ready 1 KM13 Koppelrelais
B4 Thermostaat zwembadwater / SG Ready 2 KM16 Koppelrelais
KM18 Koppelrelais
F1 Zekering 5x20 / 4,0AT K31.1 Aanvraag circulatie warm water
F2 Zekering 5x20 / 4,0AT M13 Verwarmingscirculatiepomp
F3 Zekering 5x20 / 4,0AT M15 Verwarmingscirculatiepomp 2e /
3e verwarmingskring
M16 Additionele circulatiepomp
H5 Lampje storingsindicatie op afstand M18 Sanitair-water-oplaadpomp
J1 Spanningsvoorziening N1 M20 Verwarmingscirculatiepomp
3e verwarmingskring
J2 Analoge ingangen M21 Mengkraan
M22 Mengkraan 2e verwarmingskring
J4 Analoge ingangen M24 Circulatiepomp warm water
J5 Digitale uitgangen N1 Regelaar
J6 Analoge uitgangen N14 Bedieningspaneel
J7 Digitale ingangen NO Warmtepomp
N24 Smart RTC
J9 vrij P1 Warmtehoeveelheidsmeter (optie)
J10 Bedieningspaneel R1 Buitenvoeler
R2 Terugloopvoeler
J11 vrij R2.2 Aanvraagvoeler
J12 230 VAC-uitgangen, besturing systeemcompo-
nenten
R3 Warmwatervoeler
J13 230 VAC-uitgangen, besturing systeemcompo-
nenten
R5 Voeler 2e verwarmingskring
J14 230 VAC-uitgangen, besturing systeemcompo-
nenten
R13 Voeler 3e verwarmingskring / voeler regeneratief
J15 230 VAC-uitgangen, besturing systeemcompo-
nenten
T1 Transformator 230 / 24 VAC
J16 230 VAC-uitgangen, besturing systeemcompo-
nenten
X1 Klemmenstrook
J17 230 VAC-uitgangen, besturing systeemcompo-
nenten
WP Spanningsuitgang warmtepomp
J18 230 VAC-uitgangen, besturing systeemcompo-
nenten
J25 BUS warmtepomp Kabel
J26 BUS Smart RTC
K20 Contactor 2e warmtegenerator E10
K21 Contactor elektrische dompelweerstand warm
water E9
K22 EVB-veiligheidsschakelaar
!
"
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Weishaupt WPM 5.0M at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Weishaupt WPM 5.0M in the language / languages: Dutch as an attachment in your email.

The manual is 2.01 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Weishaupt WPM 5.0M

Weishaupt WPM 5.0M User Manual - German - 24 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info