Temperatur Luftfeuchtigkeit Anforderungen bzgl.
EMV Niederspannungsrichtlinie
Im Betrieb: max. 80% rel. Feuchte Richtlinie 89/336/EWG Richtlinie 72/23/EWG
-15°C*…+40°C keine Betauung EN 50081-1 EN 60335
Transport/Lagerung: EN 50082-1
-20…+7C
* Bei entsprechend geeignetem Heizöl und/oder entsprechender Ausführung der Ölhydraulik
8.5 Zulässige Umgebungsbedingungen
8 Technische Daten
8.1 Brennerausstattung
8.2 Arbeitsfeld
Brenner Feuerungs- Motor Stellantrieb Gebläse- Zünd- Flammen- Ölpumpe
Typ manager rad gerät wächter
WL20/1-C; W-FM10 ECK 04/F-2 STD 4.5 160x60 W-ZG01 QRB1B AT2 45C
Ausf. Z 230V, 50Hz BO. 36/6-4NL
2750 min-1 24V; 3,5W
WL20/2-C; 0,25 kW, 1,5 A AL30 C 9537
Ausf. Z Kond. 8 µF
Brennertyp WL20/1-C, Ausf. Z WL20/2-C, Ausf. Z
Flammkopf W20/1-C W20/2-C
Feuerungs- 50…120 kW 70…200 kW
wärmeleistung 4,2…10,1 kg/h 5,9…16,8 kg/h
8.3 Zulässige Brennstoffe
Heizöl DIN 51603-1
Österreich: Heizöl EL nach ÖNORM-C1109
Schweiz: Standard-Heizöl, Euro-Qualität oder vorzugs-
weise Öko-Heizöl, CH-Qualität (SN 181 160-2)
8.4 Elektrische Daten
Netzspannung ______________________________ 230 V
Netzfrequenz ________________________________ 50 Hz
Leistungsaufnahme Start ___________________ 0,43 kW
Betrieb __________________0,32 kW
Stromaufnahme ______________________________ 1,5 A
Externe Gerätesicherung __________________ 16 A träge
Interne Gerätesicherung W-FM10___________6,3 A träge
Feuerungswärmeleistung
50 60 70 80 90 100 110 120
-1,5
-1,0
-0,5
0
0,5
1,0
1,5
2,0
2,5
3,0
45678910
kW
kg/h
Feuerraumdruck [mbar]
Feuerungswärmeleistung
60 80 100 120 140 160 180 200
-1,5
-1,0
-0,5
0
0,5
1,0
1,5
2,0
2,5
3,0
5 6 7 8 9 1011121314151617
kW
kg/h
Feuerraumdruck [mbar]
Arbeitsfelder nach EN 267
Die Leistungsangaben sind
bezogen auf eine Ansaug-
lufttemperatur von 20°C und
Aufstellungshöhe von 500m
34


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Weishaupt WL20-1-C at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Weishaupt WL20-1-C in the language / languages: German as an attachment in your email.

The manual is 1.47 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Weishaupt WL20-1-C

Weishaupt WL20-1-C User Manual - English - 84 pages

Weishaupt WL20-1-C Installation Guide - Dutch - 32 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info