TABLE 3
11.3 SCALE DIVISION , DECIMAL POINT
1 = ON (switch high) 0 = OFF (switch down)
In the data strings “weight” and “setpoint” the weight value is expressed without the decimal point.
However the selected value of the scale division has been integrated.
The position of the decimal point can be extracted from digit 14 of the “weight” string according to the next table:
Dil switch nr.
Code
in digit 14 of the
“weight” string
Adjusted number of
span counts will be
multiplied by:
53 54 55 56
0 0 0 0 @ x 0,001
0 0 0 1 A x 0,002
0 0 1 0 B x 0,005
0 0 1 1 C x 0,01
0 1 0 0 D x 0,02
0 1 0 1 E x 0,05
0 1 1 0 F x 0,1
0 1 1 1 G x 0,2
1 0 0 0 H x 0,5
1 0 0 1 I x 1
1 0 1 0 J x 2
1 0 1 1 K x 5
1 1 0 0 L x 10
1 1 0 1 M x 20
1 1 1 0 N x 50
1 1 1 1 O A/D converter 1 : 150.000
Example scale division selection:
The weight reading of a 1500 kg scale requires a scale division of 0,5 kg.
So the switch selection of 53 till 56 has to be selected as : 1 . 0 . 0 . 0
In the data string “weight” in digit 14 the letter H will be transmitted.
Manual 348-2 V 3.1 Page 41 01-06-2007
41


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Weightec 348 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Weightec 348 in the language / languages: English as an attachment in your email.

The manual is 1,66 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Weightec 348

Weightec 348 User Manual - Dutch - 49 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info