2.1 METROLOGY CERTIFICATES
Test Certificate nr. TC 5164 : EC Metrology Legislation: n < 10,000, e > 0.3 µV, impedance > 58 ,
and Approval nr. T 5170 loadcell cable length is not limited, no EMC precautions are required
CE marking : Based on 50081-1, EN 50082-1, EN 61000-3-2 and EN 45501.
2.2 LOADCELL EXCITATION
Voltage : 4.5 - 6.5 VAC, sine wave 218 Hz, short circuit protected
Current : 150 mA, max 8 loadcells of 350 each
Sense return : 6 wire connection, the sense signal is implemented in the A/D conversion,
so no special stabilization of the excitation voltage is provided
Loadcell cable : 6 wires, twisted pairs, low capacity, metal foil screened,
article nr. 32 TPST. No cable length limitation.
2.3 LOADCELL INPUT SEE FOR CONNECTIONS PAGE 24
Impedance (dynamic) : 20 M, 10 nF parallel, short circuit protected and excitation voltage proof
Sensitivity : 0.9 nV per division
Noise (A/D converter incl.) : 2.7 nV pp
Sensitivity settings : 0 . . . 0.25 mV/V up to 2 mV/V, in 8 steps of 0.25 mV/V, see table 1
Measuring range : 0 . . . 1.25 mV up to 0 . . . 13 mV, dependent of the sensitivity setting
Dead load compensation : Max 1 mV/V, up to 0.25% accuracy settable by switches,
moreover up to 0.0007% digital with the (auto-)zero function
Linearity adjustment : Contra parabola, effective over the net measuring range (overload setting),
range 0.09% in + and -, settable per 0.006%
2.4 A/D CONVERTER, DIGITAL SYSTEM
Principle : 21 bit continuous integrating ratio measurement
Integration time : 2,3 msec. per complete conversion, 436 Hz
Resolution internal : 1,501,500 counts, used at adjustment, zero setting, no motion detector,
taring, internal display reading en setpoint comparators
Resolution external Data output 15,015 divisions, setpoint data input 150,000 divisions,
output A/D converter max 2,000,000 counts
Stability noise : 3 counts pp at 150,000 counts, amplifiers and A/D converter included
2.5 DEFAULT DAMPING, FILTERS
Internal : 4.7 Hz one pole filter in the A/D converter
Settable : Digital two pole filter, settable from 0.13 Hz up to 4.02 Hz in 8 steps,
see table 2
Auto adaptive : Progressive increasing damping at approach of standstill,
increasing up to tot 0.07 Hz
Manual 348-2 V 3.1 Page 7 01-06-2007
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Weightec 348 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Weightec 348 in the language / languages: English as an attachment in your email.

The manual is 1,66 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Weightec 348

Weightec 348 User Manual - Dutch - 49 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info