3 | Operation
4 / 10 9035350B OI Thermo Top pro 120 _ 150
NOTE
Use suitable Webasto control elements approved for
use with the heater.
2.2.2 Avoiding damage to property
NOTE
Incorrect handling
uProtect the heater against mechanical stress (e.g.
dropping, impacts or knocks).
uDo not stand on the heater.
uDo not place any objects on top of the heater.
uAvoid shutting down the heater incorrectly during
the after-running period. After switching off via the
control element, the fan of the heater continues to
run.
uAlways switch off the heater via the control ele-
ment.
uDo not disconnect from the power supply until the
after-running period has elapsed.
DANGER
Risk of injury from the defective unit
Do not operate a defective Thermo Top Pro 120 | 150
and put it out of service by removing the fuse:
- prolonged heavy smoke development.
- unusual burner noise.
- smell of fuel.
- permanent fault switch-offs with error messages (flash
code).
- damaged heater.
uContact a Webasto service workshop.
DANGER
Risk of explosion from explosive and flammable
hazardous goods
For hazardous material vehicles, restriction of the
heater operation (ADR) is required to prevent severe
burns.
uDo not operate the heater at hazardous material
loading points.
uDo not operate the heater when loading and un-
loading hazardous materials.
NOTE
After switching off via the control element, the heater
switches to a short controlled run-on phase. Switching
off incorrectly, without after-run, can cause damage to
the Thermo Top Pro 120 | 150.
uAlways switch off the Thermo Top Pro 120 | 150 via
the control element.
NOTE
After switching off via the control element, the fan of
the heater continues to run (shortened to 40 s for ADR).
Switching off incorrectly, without after-run, can cause
damage to the Thermo Top Pro 120 | 150.
uAlways switch off the heater via the control ele-
ment.
uThe use of programmable control elements in ADR
vehicles is not permitted.
NOTE
The heater is not approved for the purpose of directly
heating the cargo area of ADR vehicles (hazardous sub-
stance transportation).
2.3 Regulations and legal requirements
üRegulations in the Installation Instructions must be ob-
served.
3 Operation
NOTE
Hazardous material vehicles (ADR) must not be
switched on or off using a timer control or remote con-
trol.
Observe additional requirements from the operating
and installation instructions for the Thermo Top Pro 120
| 150 and the control element.
3.1 Control elements
The Thermo Top Pro 120 | 150 can be fitted with various con-
trol elements:
2
3
Fig.1
1 Rocker switch
2 MultiControl or SmartControl
3 ThermoCall TC4
A combination of control elements is also possible.
üObserve the Operating instructions for the control element.
3.2 Setting up a vehicle heating system
NOTE
Depending on the type of vehicle, the air-conditioning
system can perform these settings automatically or
partly autonomously. Ask your specialist dealer to ex-
plain the optimum settings.
1. Before switching on the heater (with the ignition on), set
the vehicle heating system to “warm”.
2. Set the vehicle fan to the lowest setting (lower power con-
sumption).
3.3 Switch the heater on and off
The heater is switched on and off by different switch signals.
Depending on the system equipment, the switch signals are
produced by a switch, control element or a climate control sys-
tem.
DANGER
Danger of explosion and suffocation
For ADR vehicles: The heater must only be switched on
manually via a switch. The heater must not be switched
on automatically via a programmable switch.
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Webasto Thermo Top Pro 120 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Webasto Thermo Top Pro 120 in the language / languages: English as an attachment in your email.

The manual is 6.52 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Webasto Thermo Top Pro 120

Webasto Thermo Top Pro 120 User Manual - German - 11 pages

Webasto Thermo Top Pro 120 User Manual - Dutch - 11 pages

Webasto Thermo Top Pro 120 User Manual - French - 11 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info